Chapter 2: Installation
Installing the DALLIS Unit(s)
Power
DALLIS rear view
DALLIS internal view
Depending on your system specification, each DALLIS can be delivered with single or dual redundant power
supply units (PSUs).
When a redundant PSU is fitted (type 940/16), the load is shared between the two supplies.
The PSUs are hot pluggable. For details on how to change a PSU, see
Warning
All devices
MUST
be connected to the mains using the three-cord power leads supplied with the system.
When running with two mains supplies (PSU 1 and PSU 2), make sure that both circuits lie on the same
ground potential. Otherwise, an internal bridge of two ground wires will lead to a ground loop!
Power Consumption
The power consumption of the DALLIS varies from a minimum of 70W to a maximum of 180W, depending on the
amount and type of I/O cards fitted, and whether there are dual power supplies.
Electrical Voltage
3RU frame, PSU specification:
·
Input: 100-240 VAC (PFC)/ 48-62 Hz/ 1.6-2 A
·
Output: 12 VDC / 8.3-11 A
6RU frame, PSU specification:
·
Input: 100-240 VAC (PFC)/ 48-62 Hz/ max. 2A
·
Output: 12 VDC / 11 A
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...