mc²56 MKII Technical Manual
V5.10.2/1
62
Chapter 2: Installation
Installing the Control Surface
Power Consumption
The maximum power consumption, per mains connection, for a fully loaded frame is:
·
Current (max): 1.4 A to 3.4 A (depending on the voltage)
·
Power (max): 340 Watts
A control surface with fewer panels requires less current and power.
Due to the power supply inrush current, no more than three PSU blocks should be used per 16 A circuit breaker.
Frame Spec & (Part Number)
No. of PSU blocks per phase
16C (959-09)
1
16 + 16C (959-10)
1
16 + 16C + 16 (959-11)
1
32 + 16C + 16 (959-12)
2
32 + 16C + 32 (959-13)
2
16 Fader Extender (959-22)
1
Electrical Voltage
The specification for each PSU block is:
·
Input: 100-240 VAC (PFC)/ 47–63 Hz
·
Output: 13 VDC / 18 A (max)/ 234 Watts (max)