mc²56 MKII Technical Manual
V5.10.2/1
211
Chapter 3: AdminHD
Core Configuration: Parameters
Signal Out -> Signal
Signal Out
parameters depend on the type of signal (Line, AES, SDI, etc.). Below are two examples. See also
Line Signal Out Parameters
AES Signal Out Parameters (with SRC)
HLSD
See
Signal name
See
Signal label
See
Group
See
.
Sampling frequency
Word length
SRC
For AES cards with SRC only.
Sets the sample rate and word length for the output.
Note that the
SRC
field cannot be edited and shows the status of the sample rate
converter. To disable the SRC, you
must
set the
Sampling frequency
to
System
and
Word length
to
24
-bit. For all other combinations, SRC is always enabled.
Users can change these parameters later, from the console GUI's
Signal Settings
display.
AES consumer format
For AES cards released after 2006.
Sets the channel status of the AES output to either
Consumer
or
Professional
.
Please refer to the AES3 standard definition for details.
For details on an individual card's parameters, please refer to the relevant data sheet available in the
"
" guide.
To make a digital path suitable for Dolby E operation, you should turn off the I/O DSP for both the input and
output, and disable any sample rate conversion.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...