Redundancy
Link & Port Redundancy
For crucial interconnections between say a DALLIS and mc
2
/Nova I/O Module, you can specify either link, or link
and port, redundancy:
·
Link Redundancy
– two physical connections (MADI or RAVENNA) are made from the DALLIS master
board to the mc
2
/Nova module. If the active link fails, then the redundant link ensures an automatic
recovery.
·
Link & Port Redundancy
- two master boards are fitted to each DALLIS, and connect to different
mc
2
/Nova ports (preferably on a different module). Port redundancy provides automatic recovery from a:
o
Failure of the active physical link (MADI or RAVENNA).
o
Malfunction of the active DALLIS master board.
o
Malfunction of the mc
2
/Nova module.
To specify link redundancy:
·
MADI - order a double-port
and
·
RAVENNA - install both the copper and fibre optic connections from the RAVENNA
To specify link & port redundancy:
·
MADI or RAVENNA - order two
per DALLIS plus enough single-port
support the connections.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...