mc²56 MKII Technical Manual
V5.10.2/1
304
Chapter 5: mcx System Update
Updating the System
Script-based Update
Updating the mc
2
36 Local IO or Compact IO devices can require a script-based approach which has to be used
once – after the update to 5.6, all further updates will be automatic.
For the script-based update please follow the steps below:
·
Open a telnet or ssh connection to the mc
2
36 control system IP address, and login with username =
root
and password =
hong
·
In the command line interface, enter
updateImxIos LocalIO
to update the internal Local IO device.
·
If a Compact IO device is attached to one of the external RAVENNA ports,then use the following syntax:
o
updateImxIos CompactIO 6 1
if the Compact IO is attached to RAVENNA port 1
o
updateImxIos CompactIO 6 2
if the Compact IO is attached to RAVENNA port 2
o
updateImxIos CompactIO 6 3
if the Compact IO is attached to RAVENNA port 3