Redundancy
Automatic Takeover
If the main Router Module fails, then the redundant module automatically takes over. This ensures a seamless
recovery without any interruption to operation.
Note that a brief interruption to audio will occur while routes are reconfigured.
The redundant control system is automatically activated if, internally, a loss of connection is noticed by the
redundant system. This could be due to a software failure, hardware error or reboot of the main control system.
If the
connection between the control surface and Router Module fails, then an automatic takeover does
not
occur, as the failure could be deliberate (for example, if you disconnect the cable).
Instead the operator is presented with an error message:
1.
Click on the message and a confirmation pop-up appears:
2.
Select
Yes
to switch to the redundant control system or
No
to cancel.
Selecting
Yes
causes an interruption to the audio.
If you select
No
, then you
MUST
fix the problem with the connection before you will regain control of the audio.
Содержание mc256 MKII
Страница 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Страница 146: ...mc 56 MKII Technical Manual V5 10 2 1 146 Chapter 3 AdminHD Core Configuration Defining the System...
Страница 228: ...mc 56 MKII Technical Manual V5 10 2 1 228 Chapter 3 AdminHD The Main Menus Window Shows or hides the sub windows...
Страница 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Страница 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Страница 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...