background image

       

  Zinexts Life Science

 

 

 

 

 

 

Automated Nucleic Acid Purification System 

 

ZiXpress 64 DX system 

 

 

 

Catalog No.: ZP01022 
Rev. Date: 13.05.2022 
Manual No.

 

QW-IH01-07 

Version: 1.3 
For General Laboratory Use Only.                         

 

 

Instruction Manual 

Obelis s.a.

 

Bd Général Wahis 53 

 

1030 Brussels Belgium

 

Tel: +(32) 2 732-59-54

 

Fax: +(32)2 732-60-03

 

[email protected]

 

 

Содержание ZiXpress 64 DX system

Страница 1: ...ystem ZiXpress 64 DX system Catalog No ZP01022 Rev Date 13 05 2022 Manual No QW IH01 07 Version 1 3 For General Laboratory Use Only Instruction Manual Obelis s a Bd G n ral Wahis 53 1030 Brussels Belg...

Страница 2: ...nvironment Requirements 6 2 4 Dimension and Weight 7 3 Instrument Overview 8 4 Installation 10 4 1 Composition of the ZiXpress DX64 system 10 4 2 Operating Environment Conditions 12 4 3 Initial Settin...

Страница 3: ...system the majority of nucleic acid purification processes will be done automatically inside of ZiXpress 64 DX system it dramatically reduce the human error and use the lab force much more efficientl...

Страница 4: ...ors damage or other unexpected events resulting from miscarried following safety guideline Safety Symbols Labels Safety The meanings of safety precaution marks are as follows Warning WARNING indicates...

Страница 5: ...each If you heard or smelled anything during the operation please immediately disconnect the power and contact your local representative agent Caution Never attempt to remodel the ZiXpress 64 DX syste...

Страница 6: ...lways wear appropriate gloves a mask and safety goggles etc when handling any infectious samples About Infectious Wastes When handling or disposing of infectious materials follow the laboratory guidel...

Страница 7: ...ples per batch Consumable 2 2 ml 96 Deep Well Plate Collection Efficiency 100 copies mL positive detecting rates 95 Inter Well Purification Accuracy CV 3 Heat Block Temperature Room temperature to 80...

Страница 8: ...Page 7 Dimension Weight Dimensions 722 x 360 x 490 mm Weight 38 kg EMC EN61326 1 Safety EN60101 1 EN60101 2 Transportation Environment temperature 20 55 C Relative humidity 80...

Страница 9: ...Page 8 INSTRUMENT OVERVIEW Front view Rear view Touch Panel Handler Door Window Power inlet Fixing block sensor USB Port Rear cover Power switch...

Страница 10: ...Page 9 Inside view Magnetic Pillar Mixing Sleeves Reagent plate Temperature Control UV Lamp Mixing Sleeves Track...

Страница 11: ...you notice any missing part s A B C D E F Quantity A Instrument x1 B User Manual x1 C Power Cord x1 D 2 2ml Deepwell 96 Plate x4 E 8 Tip Comb x4 F Fixing block x1 Please make sure all components are f...

Страница 12: ...Deepwell 96 Plate x12 plates B 8 Tip Comb x24 pcs Note Extraction kits have to be purchased separately Please contact your local representative agent for further information The contents of extraction...

Страница 13: ...ble temperature Warming a cold room suddenly or moving the instrument from a room with low temperature to a warm room may cause condensation inside the device that might resulting in abnormal extracti...

Страница 14: ...s a slanted surface or a place subject to vibrations It may cause injury or device failure Do not use the ZiXpress 64 DX system in direct sunlight or close to a heating device It may shorten the life...

Страница 15: ...er of the instrument from two sides to move it out of the transportation box Do not hold the door or the plastic outer covering while transporting the instrument Caution Improper handling of the movem...

Страница 16: ...it in the Fixing Block Sensor Spot following the guideline below 1 Plug in the power cord to the electric outlet 2 Use a Phillips head screwdriver to release the red screws 3 Remove the Fixing Block...

Страница 17: ...Page 16 4...

Страница 18: ...sks 1 Insert Fixing Block 1 Put the Fixing Block to fix the Magnetic Pillar frame 2 Install the Fixing Block 3 Use Phillips head screwdriver for the red screw 4 Close the door 2 Disconnect the plug fr...

Страница 19: ...ent parcel Functional Descriptions Main Menu Home UV Light Light Setting Hibernate LED Light After pressing button the icon will change into the instrument s light will turn off UV Light After pressin...

Страница 20: ...adjustment check test Sleeping mode After pressing button the instrument will get into the sleeping mode If you want to wake up the instrument touch the screen again Note Before getting into the sleep...

Страница 21: ...oves and a mask since the device may be contaminated Important Before starting the extraction put on appropriate gloves a mask and safety goggles if required by the operation Be careful not to contami...

Страница 22: ...2 Connect the plug of the power cable to the outlet 3 Turn the power switch on and wait for the Touch Panel to turn on and displaying ZiXpress 64 DX system initializing The system will process self t...

Страница 23: ...Page 22 4 Open the door 5 Set up the mixing sleeves on the mixing sleeve track Caution Make sure the sleeves have entered completely...

Страница 24: ...Page 23 6 Remove carefully the aluminum foil sealing membrane on the reagent plate Add samples to Well 1 and Well 7 7 Place the reagent plate s into the instrument...

Страница 25: ...Page 24 8 Close the door before starting the instrument 9 Select protocol Select the pre installed protocols This figure is the standard protocol in ZiXpress 64 DX system...

Страница 26: ...xtraction process Note The process time and remaining process time will be displayed on the screen 11 While the extraction procedure is finished transfer the extracted products located at Well 6 and W...

Страница 27: ...C long term before performing any downstream analysis 12 Discard the used consumables into biohazard waste 13 If you are not using the instrument in short term press button to get into sleeping mode...

Страница 28: ...Page 27 2 To restart the procedure press button Stop the Process 1 During the process if you want to stop pause the procedure please press button 2 To stop the process press button...

Страница 29: ...ansfer the extracted products located at Well 6 and Well 12 into nuclease free tubes Note You can apply quality checking do downstream study or storage them as what you expect 2 Remove the used plasti...

Страница 30: ...trument body by removing dust gently with a dry soft cloth If the outside of the ZiXpress 64 DX system is heavily soiled or if any samples that may cause infection are adhered to the outside of the Zi...

Страница 31: ...testing program does not run Forget to remove the fixing block from instrument Turn off the instrument and remove the fixing block Technical problem Contact your local representative agent The beepin...

Страница 32: ...Address 16F No 93 Sec 1 Xintai 5th Rd Xizhi Dist New Taipei City 221416 Taiwan R O C Tel 886 2 2246 3579 Fax 886 2 2242 1179 Mail info zinexts com Product of Origin Taiwan R O C Technical Support Zine...

Страница 33: ...r any problem that is caused by i Conditions malfunctions or damage not resulting from defects in material or workmanship ii Any consumption spare parts including fuses light bulbs UV lights LED light...

Страница 34: ...Page 33 Zinexts Life Science Corp www zinexts com 16F No 93 Sec 1 Xintai 5th Rd Xizhi Dist New Taipei City 221416 Taiwan R O C Tel 886 2 2246 3579 Fax 886 2 2243 8570 Mail info zinexts com...

Отзывы: