
MEDIA: Page Menu Commands Load selected
717
The Programs and Combinations will be loaded in order
from the bank and number you specify.
Content loaded from the .PCG file
This command loads:
• Drum Kits or Wave Sequences which use at least one
SAMPLING mode Sample or Multisample.
• Programs which use at least one SAMPLING mode
Multisample, or one Drum Kit or Wave Sequence as
described above.
• Combinations which use at least one Program as
described above.
Content loaded from the .SNG file
The command also loads Songs which use at least one
Program as described in (2), above.
These Songs will be loaded into vacant numbers starting
after the last Song in internal memory. For more
information, see “.SNG Allocation” on page 703.
Automatic reassignment of banks and numbers
When loading, the banks and numbers for all data will be
adjusted automatically so that all references work correctly.
This includes:
• SAMPLING mode Samples used by Multisamples and
Drum Kits
• SAMPLING mode Multisamples used by Programs and
Wave Sequences
• Drum Kits and Wave Sequences used by Programs
• Programs used by Combinations or Songs
1. Select a .PCG file in the directory window.
2. Select this command to display the dialog box.
This command will be available only if you’ve selected a
.PCG file.
3. If you also want to load the .SNG file of the same
name as the .PCG file, check the “Load
********.SNG too” check box.
Note:
The .KSC file of the same filename as the .PCG file
will be loaded together with the .PCG file. If the file does
not exist in the current directory, load the file as described
in “If a file to be loaded cannot be found, or when loading
a file that was saved across media” on page 702.
4. If you check “Load ROM-Program in Combi/Song
too,” ROM-based programs in the .PCG file
combinations or .SNG file songs will be loaded
together with the Programs which use SAMPLING
mode data.
Choose this setting if the Combinations or Songs being
loaded rely on both user and preload Programs. This is
the default.
If you leave this unchecked, only Programs, Drum Kits,
and Wave Sequences which use SAMPLING mode data
will be loaded, along with any Combinations or Songs
which use those Programs.
(To ensure that those Combinations and Songs sound
correctly, all Programs that they require will also be
loaded, even if they use only ROM data.)
Program data whose bank type is EXi will not be loaded.
5. Use “Append to: Combination” to specify the loading-
destination bank and number for the combinations in
the .PCG file.
When you execute, only the applicable combinations will
be loaded into consecutive numbers starting at the bank
and number you specify here.
6. Use “Append to: Program” to specify the loading-
destination bank and number of the programs in the
.PCG file.
When you execute, only the applicable programs will be
loaded into consecutive numbers starting at the bank and
number you specify here.
If the loading-destination bank and number exceed N127,
loading will automatically stop.
If the load-destination bank and number in steps 5 and 6
exceeds USER-G127, the load operation will end
automatically.
7. Use “Append to: Drum Kit” to specify the loading-
destination number for the drum kits in the .PCG file.
When you execute, only the applicable drum kits will be
loaded into consecutive numbers starting at the number
you specify here.
8. Use the Append to “Wave Sequence” field to specify
the load-destination number for the wave sequences in
the .PCG file.
When you execute the command, only the valid wave
sequences will be loaded starting at the number you
specify, and occupying each consecutive number.
If the load-destination bank and number in steps 7 and 8
exceeds USER-G15–USER-G31 respectively, the load
operation will end automatically.
The data in the locations following the specified
bank/number will be rewritten when you load. If you
want to keep this data, use
Save All
or
Save PCG
before
you load the new data.
9. Press the OK button to load the data. If you decide not
to load, press the Cancel button.
Cautions regarding Save
When saving combinations with
Save All
,
Save PCG &
SNG
, or
Save PCG
, you should also try to save the
programs used by each timbre (and the drum kits, wave
sequences used by the programs) at the same time.
Similarly, when saving programs, you should also save
the drum kit, wave sequence used by the program and the
wave sequence at the same time.
If multisamples or samples created in SAMPLING mode
are used in a program or drum kit, we recommend that
you save the data using
Save All
.
Содержание NAUTILUS Series
Страница 1: ...i Parameter Guide E 1...
Страница 264: ...EXi STR 1 Plucked String 254...
Страница 358: ...EXi MOD 7 Waveshaping VPM Synthesizer 348...
Страница 368: ...EXi SGX 2 Premium Piano 358...
Страница 458: ...SEQUENCER mode 448 Track 02 16 Track Number For more information please see Track 01 Track Number on page 446...
Страница 568: ...SEQUENCER mode 558...
Страница 580: ...SET LIST mode 570...
Страница 738: ...MEDIA mode 728...
Страница 753: ...Insert Effects IFX1 IFX12 Routing 743 Fig 2 2e...
Страница 961: ......