Table 46: AC Power Cord Specifications for a Single-Phase Wiring Tray
(continued)
Plug Standards
Electrical Specifications
Country/Region
CEE(7) VII Type VIIG
250 VAC, 16 A, 50 Hz
South Korea
SEV 5934-2 Type 23G
250 VAC, 16 A, 50 Hz
Switzerland
BS 1363/A Type BS89/13
250 VAC, 13 A, 50 Hz
United Kingdom
Related
Documentation
AC Power Supply in a QFX3008-I Interconnect Device
•
•
General Electrical Safety Guidelines and Warnings
•
AC Power Electrical Safety Guidelines
•
AC Power Disconnection Warning
•
Connecting AC Power to a QFX3008-I Interconnect Device with Single-Phase Wiring
Trays on page 176
AC Power Cord Specifications for a QFX3008-I Interconnect Device with Three-Phase
Delta Wiring Trays
Supported Platforms
QFX3000-G
Most sites distribute power through a main conduit that leads to frame-mounted power
distribution panels, one of which can be located at the top of the rack that houses the
device. An AC power cord connects each wiring tray to the power distribution panel.
WARNING:
The QFX3008-I Interconnect device is pluggable type A equipment
installed in a restricted-access location. It has a separate protective earthing
terminal provided on the chassis in addition to the grounding pin of the power
supply cord. This separate protective earthing terminal must be permanently
connected to earth.
CAUTION:
Power cords and cables must not block access to device
components or drape where people could trip on them.
Each three-phase AC wiring tray has a metal wiring compartment that contains the AC
terminal block and ground. There are two types of three-phase wiring trays:
delta
(three-wire) and
wye
(four-wire). The
delta
AC terminal block consists of three input
terminals labeled
L1
,
L2
, and
L3
, from top to bottom in the common three-phase naming
convention.
You must provide cords appropriate for your geographical location. The AC power cord
wires insert into the AC terminal block on the wiring tray.
135
Copyright © 2015, Juniper Networks, Inc.
Chapter 8: Power
Содержание QFX3000-G QFabric
Страница 12: ...Copyright 2015 Juniper Networks Inc xii QFX3000 G QFabric System Deployment Guide...
Страница 28: ...Copyright 2015 Juniper Networks Inc 2 QFX3000 G QFabric System Deployment Guide...
Страница 102: ...Copyright 2015 Juniper Networks Inc 76 QFX3000 G QFabric System Deployment Guide...
Страница 108: ...Copyright 2015 Juniper Networks Inc 82 QFX3000 G QFabric System Deployment Guide...
Страница 154: ...Copyright 2015 Juniper Networks Inc 128 QFX3000 G QFabric System Deployment Guide...
Страница 168: ...Copyright 2015 Juniper Networks Inc 142 QFX3000 G QFabric System Deployment Guide...
Страница 180: ...Copyright 2015 Juniper Networks Inc 154 QFX3000 G QFabric System Deployment Guide...
Страница 270: ...Copyright 2015 Juniper Networks Inc 244 QFX3000 G QFabric System Deployment Guide...
Страница 294: ...Copyright 2015 Juniper Networks Inc 268 QFX3000 G QFabric System Deployment Guide...
Страница 300: ...Copyright 2015 Juniper Networks Inc 274 QFX3000 G QFabric System Deployment Guide...
Страница 394: ...Copyright 2015 Juniper Networks Inc 368 QFX3000 G QFabric System Deployment Guide...
Страница 468: ...Copyright 2015 Juniper Networks Inc 442 QFX3000 G QFabric System Deployment Guide...
Страница 470: ...Copyright 2015 Juniper Networks Inc 444 QFX3000 G QFabric System Deployment Guide...
Страница 608: ...Copyright 2015 Juniper Networks Inc 582 QFX3000 G QFabric System Deployment Guide...
Страница 639: ...PART 5 Troubleshooting QFabric System Troubleshooting on page 615 613 Copyright 2015 Juniper Networks Inc...
Страница 640: ...Copyright 2015 Juniper Networks Inc 614 QFX3000 G QFabric System Deployment Guide...