Section 6: Programming
l
HSM2300 1 – 4
l
HSM2208 01 – 16
l
HSM3204CX
l
HSM3408
l
HSM3350
OFF – does not activate if a module supervisory trouble is detected.
14 – Module Tamper
ON – activates if any of the following module tamper conditions is present:
l
HSM2HOST
l
Keypad 01 – 32
l
Zone expander 01 – 30
l
HSM2204 1 – 4
l
HSM2300 1 – 4
l
HSM2208 01 – 16 tamper troubles
l
HSM3204CX
l
HSM3408
l
HSM3350
OFF – does not activate if a module tamper condition is present.
15 – Communications
ON – activates if any of the following communications conditions is present:
l
TLM trouble
l
FTC receiver 1 – 4
l
SIM Lock trouble
l
Cellular Trouble
l
Ethernet Trouble
l
Receiver 1 – 4 absent
l
Receiver 1 – 4 supervision trouble
l
SMS Configuration trouble
l
Alt comm. Fault.
OFF – does not activate if a communications trouble condition is present.
16 – Not Networked
ON – activates if any of the following not networked conditions is present:
l
Zone 001 – 248
l
Keypad 01 – 32
l
Siren 01 – 16
l
Repeater 01 – 08
l
User 01 – 1000 (wireless keys) not networked troubles
OFF – does not activate if a not networked trouble condition is present.
156 – Latched System Event
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
02 – Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 – Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 – Panic Alarm
ON: activates on panic alarm (audible or silent).
OFF: does not activate on panic alarm.
06 – Burglary Alarm
ON: activates on burglary alarm.
OFF: does not activate on burglary alarm.
- 106 -