Section 2: Installation
HSM3204CX in HSC3020C wiring diagram (EU)
This diagram shows routing of power limited and non-power limited wiring inside the enclosure. Battery leads and AC cord are non-
power limited. All other wiring is power limited.
Figure 2-19: HSM3204CX wiring for HSC3020C enclosure
Callout
Description
1
Power limited wiring entry/exit point
2
Tamper switch and mounting bracket
3
HSM3350
4
Cable ties
5
Fuse (replace fuse with same type 20 mm rated 250 V / 3.15 A slow blow)
6
AC in (blue/neutral)
7
EGND (green/yellow)
8
AC in (brown - live)
9
To power adapter module (brown - live)
10
To power adapter module (green/yellow - EGND)
11
To power adapter module (blue - neutral)
12
Power adapter
13
Power adapter mounting screws
14
Battery: 1 x 17 Ah / 12 V or for NFA2P 1 x 18 Ah / 12 V sealed lead acid battery type
15
Cabinet
16
PC board
17
Standoff
Power supply
Primary: 100 VAC to 240 VAC, 50 Hz to 60 Hz, Class 6; Secondary: 18 VDC, 3.6 A
Power supply adapter module: HS65WPS
- 31 -