Section 5: System operation
Trouble
option
Trouble description
[02]
Keypad 01-32 Not Networked: Generated when a keypad becomes out of sync with the wireless network or has not been
synchronized with the network after enrollment.
[03]
Siren 01-16 Not Networked: Generated when a siren becomes out of sync with the wireless network or has not been
synchronized with the network after enrollment.
[04]
Repeater 01-08 Not Networked: Generated when a repeater becomes out of sync with the wireless network or has not
been synchronized with the network after enrollment.
[05]
User 01 - 1000 Not Networked: Generated when a wireless key becomes out of sync with the wireless network or has not
been synchronized with the network after enrollment.
Table 5-16: Trouble 13 AUX Troubles
Trouble
option
Trouble description
[05]
HSM2300: 1 A power supply AUX output voltage is out of range.
[06]
HSM2204: A high current AUX output module output voltage is out of range.
[07]
System Area: AUX output voltage is out of range.
[10]
HSM3408: The 8 zone expander AUX output voltage is out of range.
[11]
HSM3204CX: The corbus repeater AUX output voltage is out of range.
[12]
HSM3350 AUX 1 Trouble: 3 A power supply AUX output voltage is out of range.
[13]
HSM3350 AUX 2 Trouble: 3 A power supply AUX output voltage is out of range.
Table 5-17: Trouble 14 Limit exceeded trouble
Trouble
option
Trouble description
[01]
Interactive zone: The number of zones configured in the panel is not supported by Alarm.com firmware (for example >
220).
[02]
Interactive partition: The number of partitions configured is not supported by Alarm.com firmware (for example > 8).
Note:
Ensure you have the alarm controller type and version, (for example, HS3032, 1.1) and the list of modules connected to control
panel (for example, HSM2108, HSM2HOSTx and so on) available before contacting Customer Support. Version number can be
accessed by entering [*][Installer Code][900] on any keypad. This information is also located on a sticker on the printed circuit board.
[*][3] Alarm memory display
The Memory light flashes if an alarm, tamper or fault event occurred during the last armed period or while the panel was disarmed (24
hour zones). Press [*][3] to view zones in alarm memory. To clear the memory, arm and disarm the system. When viewing alarms in
memory, LCD keypads indicate the last zone that has gone into alarm first, followed by other alarms in numerical order.
This feature can be programmed to require an access code.
See "[023] System Option 11" on page 118
, option 6 for details.
A programmable function key may be configured to display alarms in memory.
See "Keypad function keys" on page 63
for details.
[*][4] Door chime enable/disable
When this feature is enabled, the keypad emits a tone when a zone programmed as a Chime type is opened or closed. Pressing [*][4]
toggles between enabled and disabled. The door chime attribute for each zone is programmed in section [002], subsections [001]-
[248] option 4.
A function key can also be programmed to enable/disable this feature.
See "Keypad function keys" on page 63
for details. This
feature may require an access code.
See "[023] System Option 11" on page 118
option 7 for details.
The following door chime sounds may be selected:
l
6 beeps
l
"Bing-Bong"
l
"Ding-Dong"