Section 6: Programming
103 – Sensor Reset [*][7][2]
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
03 – Access Code Required / No Code Required
ON: Access code required for activation
OFF: No access code required for activation
107 – External Siren
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
109 – Courtesy Pulse
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
111 – Keypad Buzzer Follow
01 – True Output/Inverted
ON: deactivated during normal operation, activated when triggered.
OFF: activated during normal operation, deactivated when triggered.
02 – Timed Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until the buzzer condition ends.
09 – Entry Delay
ON: activates on entry delay.
OFF: does not activate on entry.
10 – Exit Delay
ON: activates on exit delay.
OFF: does not activate on exit delay.
11 – Door Chime
ON: activates when chime is enabled.
OFF: does not activate when chime is enabled.
12 – Keypad Buzzer Zone
ON: activates when keypad buzzer goes into alarm.
OFF: does not activate when keypad buzzer goes into alarm.
13 – Audible Exit Fault
ON: activates when audible exit fault pre-alert begins.
OFF: does not activate when audible exit fault pre-alert begins.
14 – Auto-Arm Pre-Alert
ON: activates when auto-arming pre-alert begins.
OFF: does not activate when auto-arming pre-alert begins.
114 – Ready To Arm
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
115 – Armed Status
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.