Section 2: Installation
Output expander
The HSM2208 module is used to add up to 8 low-current programmable outputs to the alarm system.
The 4-wire Corbus connection is used by the panel to communicate with the module. Connect the RED, BLK, YEL and GRN terminals
to the Corbus terminals on the alarm panel. Board current draw: 40 mA.
Figure 2-25: HSM2208 output expander
SERIAL NUMBER
LED
SWITCH
Wireless transceiver module
The HSM2HOSTx 2-way wireless module provides communication between wireless devices and the alarm controller. The
HSM2HOST must be used with the HSC3020CP plastic enclosure, or in its own separate enclosure. Connect the HSM2HOSTx to the
4-wire Corbus of the alarm controller according to the following diagram. After you have completed the wiring, reconnect power to the
security system. Board current draw: 35 mA
Figure 2-26: HSM2HOSTx wiring diagram
Callout
Description
1
Control panel
2
Corbus to HSM2HOST
- 37 -