Section 6: Programming
If multiple zones are enabled, any active zone in that group triggers the output. The PGM will not activate again until all zones are
restored.
200 – Zone Follower - PGM By Zone
This option allows the PGM to activate when the assigned zone is opened and deactivate when the zone is restored or, if
programmed, when a valid access code is entered. This PGM follows the state of the assigned zone, regardless of the partition the
zone or PGM is assigned to.
To program which zone the PGM will follow, see
"[011] PGM Configuration Options"
[010] PGM Attributes
The following options are used to program the operating characteristics of the main bell and PGM outputs.
[000] Main Bell Mask
This programming section is used to configure the types of audible alarms that trigger the main bell output on the alarm controller. All
options are selected by default.
Fire Alarm
ON: Fire alarm ([F] key, Fire zones) activates the main siren.
OFF: Fire alarm does not activate the main siren.
CO Alarm
ON: CO alarm activates the main siren.
OFF: CO alarm does not activate the main siren.
Burglary Alarm
ON: Burglary alarm (Delay, Instant, Interior, Stay/Away, Night, Interior Delay, Instant Stay/Away, Day, 24-hour Burglary) activates the
main siren.
OFF: Burglary alarm does not activate the main siren.
24-Hour Flood Alarm
ON: Main bell activates in the event of a 24-Hour Flood alarm.
OFF: Main bell does not activate in the event of a 24-Hour Flood alarm.
Bell Squawks
ON: Squawks activate the main siren. Bell squawks must be enabled to use the following options:
l
Bell Squawk on arm (single)
l
Bell Squawk on disarm (double)
l
Bell Duration Auto-Arm (single every second)
l
Bell Squawk on Exit (single every second)
l
Bell Squawk on Entry (single every second)
l
Bell Squawk on Trouble (single every 10 seconds)
OFF: Squawks do not activate the main siren.
[001]-[324] PGM 001-324 Attributes
The following PGM attributes can be assigned to a PGM. Each attribute has various toggle options, depending on the PGM type
selected (section [009]).
101 – Fire and Burglary
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
102 – Delay Fire and Burglary
01 – True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: active during normal operation. Deactivated when triggered.
- 101 -