Section 6: Programming
[105] Ethernet Receiver 1 UDP Local Port
Default (03060)
Use this section to set the value of the UDP local outgoing port. Set the value of this port when the installation is located behind a
firewall and must be assigned a particular port number as determined by the central station system administrator. Valid range: 00000
- 65535.
[106] Ethernet Receiver 1 Domain Name
Default ( )
Enter the domain name as 32 ASCII characters.
Ethernet Receiver 2 Options
[111] Ethernet Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. The account code is used when transmitting
heartbeat signals to the central station receiver. Signals received from the control panel will use the control panel account number.
Valid range: 0000000001- FFFFFFFFFE.
Note:
If both Ethernet receiver 2 and cellular receiver 2 are the same receiver (IP and port number are identical), Ethernet receiver 2
account will be used for Ethernet and cellular.
[112] Ethernet Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the account code to identify the communicator module at the central station. Valid range: 000000 -
099999. Value is entered as leading 0 followed by the 5-digit DNIS. Format is BCD.
Note:
Each Ethernet/cellular receiver must be programmed with a unique DNIS.
[113] Ethernet Receiver 2 Address
Default (000.000.000.000)
Programming the Ethernet receiver 2 IP address with 000.000.000.000 will disable Ethernet.
Enter the Ethernet receiver 2 IP address. This address will be provided by the central station system administrator. Format is 4 fields,
each field is a 3-digit decimal. Valid range: 000-255.
Note:
When a valid IP address has been programmed, Ethernet receiver 2 is enabled and will communicate events over the Ethernet
channel.
Ethernet receiver 2 and cellular receiver 2 may be configured to communicate to the same central station receiver.
To configure the device to operate using this common receiver mode functionality, program the Ethernet receiver 2 and cellular
receiver 2 IP address and port number with the same values. When operating in common receiver mode the Ethernet receiver 2
account code will be used for communications over Ethernet and cellular.
Note:
Do not program Ethernet receiver 1 and Ethernet receiver 2 to communicate to same receiver.
[114] Ethernet Receiver 2 UDP Remote Port
Default (03061)
This section is used to program the port number used by Ethernet receiver 2. Set the value of this port when the installation is located
behind a firewall, and must be assigned a particular port number as determined by the central station system administrator. Valid
range: 00000 - 65535.
Note:
Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[115] Ethernet Receiver 2 UDP Local Port
Default (03065)
Use this section to program the value of the local outgoing port. Set et the value of this port when the installation is located behind a
firewall and must be assigned a particular port number as determined by the network administrator. Valid range: 00000 - 65535.
Note:
Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value.
[116] Ethernet Receiver 2 Domain Name
Default ( )
Enter the Domain Name as 32 character ASCII.
- 146 -