Section 6: Programming
6 – Burglary Verified
When using Cross Zoning, this reporting code is sent when two crossed zones go into alarm during the cross zone timer.
When using Police Code or sequential detection, this reporting code is sent when any two zones that have the burglary verification
attribute enabled go into alarm. Arming the system resets the zone alarm count for police code or sequential detection.
7 – Burglary Not Verified
When using Cross Zoning or sequential detection, this reporting code is sent if the cross zone timer is initiated by the first cross zone
alarm, but is not verified by a second alarm before the timer expires.
8 – Alarm Cancel
Sent when a valid access code is entered during the communications cancel window. The central station acknowledges cancellation
by providing a keypad ringback.
[002] Miscellaneous Alarm 2
1 – Holdup Verified
Sent when the configured Holdup verified conditions have been met.
Note:
Not for use with UL/ULC listed installations.
[011] Priority Alarms 1
The reporting codes in this section are sent to the Alarm & Restore call direction group and apply to all system keypads.
1/2 – Keypad Fire Alarm-[F] Key Alarm/Restore
Sent when [F] Key alarms/restores occur.
3/4 – Keypad Medical Alarm-[M] Key Alarm/Restore
Sent when [M] Key alarms/restores occur. The keypad beeps 10 times when the medical alarm is successfully communicated to the
alarm monitoring station.
5/6 – Keypad Panic Alarm-[P] Key Alarm/Restore
Sent when [P] Key alarms/restores occur.
7/8 – Auxiliary Input Alarm/ Restore
Sent when an alarm condition occurs/ is restored on PGM 2 (if configured as an input).
[021] Fire Alarms 1
3/4 – PGM 2 2-Wire Alarm/Restore
When PGM 2 is programmed as a 2-wire smoke alarm, this reporting code is sent when an alarm condition is detected and when it is
restored.
[101] Tamper Events
3/4 – Module Tamper/Restore
This reporting code is transmitted when a system module enters a tamper alarm state and uses the System Tamper Alarm and
Tamper Restore call direction.
5 – Keypad Lockout
Sent when a number of invalid access codes have been entered at a system keypad.
This reporting code is sent to the system Tamper Alarm & Tamper Restore call direction group.
7 – Remote Lockout
Sent when a number of invalid access codes have been entered through DLS or Integration. This reporting code is sent to the system
Tamper Alarm & Tamper Restore call direction group.
[201] Open/Close Events 1
1/2 – User Closing/Opening
This reporting code is transmitted when a user arms/disarms a partition and uses the Opening and Closing call direction.
5/6 – Special Closing/Opening
This reporting code is transmitted when a partition is closed/opened using quick arm ([*][0]), downloading, or Stay or Away function
keys without an access code. The Opening and Closing call direction group is used for this reporting code.
7/8 – Keyswitch Opening/Closing
This reporting code is transmitted when a keyswitch zone is used to arm or disarm the system.
- 125 -