Section 2: Installation
Installing and wiring in the HSC3020CP
The HSC3020CP enclosure ships with the PCB assembly, HS65WPS power adapter, fuse block and tamper switch, to be installed as
shown in
. The cellular communicator (if provided), case tamper switch, battery, and AC must be wired as shown in
and
. Use wire size 14 to 22 AWG.
Warning: Connect AC power and telephone lines only after all modules are installed and wiring is complete.
Note:
For NFA2P certified systems all components are pre-installed in the enclosure.
To install the components in the HSC3020CP enclosure, complete the following steps:
1. Use the six number 4 sized screws provided to screw the PCB into the enclosure.
2. Use the two number 6 sized screws provided to screw the power adapter into the enclosure.
3. Press the fuse block into the enclosure. For more information, see callout 3 in
4. Press the tamper switch into the bracket in the enclosure. For more information, see callout 4 in
5. Wire the tamper switch to the COM & ZONE terminals on the control panel. For more information, see callout 15 in
.
6. Route the AC line in through the opening on the bottom of the cabinet and secure using cable tie as shown in
.
7. Connect AC wires to the fuse block as shown in
Note:
Position cable ties over cable insulation, not directly on the exposed AC wires.
8. Wire the power adapter to the terminal block. For more information, see callout 7 to callout 12 in
.
Note:
Use cable ties to secure the power adapter cable. For more information, see callout 5 in
9. Connect the ground wire from the power adapter to the control panel. For more information, see callout 14 in
Figure 2-17: Installing components in the HSC3020CP enclosure
Callout
Description
1
Number 4 sized screws
2
Number 6 sized screws
3
Fuse block
4
Tamper switch (ensure correct orientation is observed)
- 29 -