Appendix 7: Specifications
Appendix 7: Specifications
The following table outlines the specifications of the PowerSeries Pro alarm controller.
Feature
Description
Zone configuration 32, 128, or 248 wireless zones.
Up to 8 hardwired zones.
41 zone types.
15 programmable zone attributes.
Normally closed, SEOL, DEOL, and TEOL resistor.
Fully supervised hardwired zone expansion using the HSM2108 or HSM3408.
Fully supervised wireless zone expansion using the HSM2HOST 2 way wireless integration module, or the
HS2LCDRFPROx keypad.
Access codes
4, 6, or 8 digit codes.
Up to 1003 access codes.
Note:
For EN50131-1 Grade 2 compliant systems using 100 access codes or less, 6 digit codes must be used. If
using more than 100 access codes, 8 digit codes must be used. For EN50131-1 Grade 3 compliant systems 8
digit codes must be used.
Programmable attributes.
Warning devices
2 remote, wireless warning devices.
Programmable as steady, pulsed, temporal 3, or temporal 4
For NFA2P certified systems the delay for operating the warning device shall be set to max. 10 min.
Memory
CMOS EEPROM.
Retains programming information and system status on AC or battery failure for 20 years minimum (not verified
by UL).
Power supply -
North America
HS65WPS - mounted in the same enclosure, permanently connected.
HS65WPSNA - mounted in the same enclosure or outside, cord connected.
HS65WPSNAS - hardwired, use in ULC Commercial Burg Security Level IV and ULC Commercial Fire
Monitoring applications.
Primary: 120 VAC, 60 Hz, Energy Efficiency Class VI.
Secondary: 18 V DC, 3.6 A Limited Power Source (LPS).
Power Supply -
International
HS65WPS - mounted in the same enclosure, permanently connected.
Primary: 100 VAC to 240 VAC, 50 Hz, 1.7 A, Energy Efficiency Class VI.
Secondary: 18 VDC, 3.6 A, LPS.
Note:
For installations using the power supply module mounted inside the cabinet, replace fuse only with the
same type (20 mm) rated new fuse rating 250 V / 3.15 A slow blow.
Regulated power
supply
3.6 A regulated, supervised.
Type A as per EN50131-6 Standard.
FET protected for Bell, Aux+ and Battery terminals.
Reverse battery detection/protection.
Supervision for input power and low battery.
Normal and high current battery charge options.
Supervised battery charging circuit.
- 316 -