Appendix 5: Regulatory approvals
EN50136-2:2013 Grade 2, Class II, ATS SP3 (dialer), SP4 (Ethernet), DP2 (dialer and Ethernet), DP3 (Ethernet and plug-in cellular)
when installed in enclosure models HSC3020CP.
This product is suitable for use in systems with the following notification options:
- A - use of two remotely powered warning devices and one ATS SP3 required (internal dialer or ethernet or plug-in cellular module)
- B - use of one self-powered warning device and one ATS SP3 required (internal dialer or ethernet or plug-in cellular module)
- C - use of dual path ATS DP2 required (any combination of internal dialer and ethernet and/or cellular module)
- D - use of an ATS SP4 required (internal ethernet or plug-in cellular module with encryption enabled)
- E - use of dual path ATS DP3 required (combination of internal ethernet and plug-in cellular module with encryption enabled)
For EN50131 compliant installations, with alarm control panels HS3032, HS3128 and HS3248, only the intrusion portion of the alarm
system may be activated.
For EN50131 compliant installations, the following functions must be disabled:
- Fire Alarm
- CO Alarm
- Auxiliary (Medical) Alarm functions
- In Section 861-21, options 1 and 2 must be off.
For EN50131 compliant installations, the following zone types must not be used:
Zone number
Zone type
Zone number
Zone type
Zone number
Zone type
007
Delayed 24-Hour Fire
041
24-Hour CO
049
24-Hour Flood
008
Standard 24-Hour Fire
045
24-Hour Heat
052
24-Hour Non-Alarm
025
Auto Verified Fire
046
24-Hour Medical
056
24-Hour High Temperature
027
Fire Supervisory
047
24-Hour Emergency
057
24 Hour Low Temperature
040
24-Hour Gas
048
24-Hour Sprinkler*
071
Door Bell
In this configuration, no non-mandatory events are generated in the Event Buffer and compliance with minimum 500 mandatory
events storage (Grade 3) is ensured as per Section 8.10.1 in EN50131-3. Compliance labeling should be removed or adjusted if non-
compliant configurations are selected.
Notes for EN50136-1:2012 compliant installations - applicable to integrated phone line and Eth-
ernet communicator only.
The communicator operates in pass-through mode and it does acknowledge the alarm to the compatible control panel after an
acknowledgement has been received from the compatible alarm receiver.
1. The integrated communicator is monitored by the control panel and is programmed via the menu available from the
compatible keypad connected to the alarm control panel HS3032, HS3128, HS3248.
2. The communicaton path is immune to conducted and radiated RF fields, with levels up to 10V/m as tested per EN50130-4
Standard.
3. The control panel with integrated communication module conforms with radiated emissions levels for Class B equipment as
per standards EN61000-6-3/EN55032/CISPR32.
4. The control panel has two integrated communication paths: Phone line dialer and Ethernet (IP) communication path. These
can be used in an ATS with the following categories:
l
Single Path mode SP3 (Phone line dialer) or SP4 (IP path), or
l
Dual Path mode DP2 integrated Ethernet (IP) path in conjunction with the compatible control panel
HS3032/HS3128/HS3248 integrated PSTN communicator, or
l
Dual Path DP3 integrated Ethernet (IP) path in conjunction with the plug-in cellular module 3G9080-EU or GS9080.
5. The integrated Ethernet (IP) communication path uses sequential authentication for substitution security and encryption
AES128 bit for information security. The AES128-bit key is validated by NIST, Certificate No. 5371.
6. The integrated communicators have been tested for compliance in conjunction with the following applicable standards:
EN50136-1:2012, EN50136- 2:2013, EN50131-10:2014, Grade 3, Class II, ATS configuration: SP3, DP2, DP3. For EN50131-
1:2006/A1:2009 /A2:2017 compliant installations, the following programming options must be set as described: Supervision
heartbeat set to 180 seconds for SP4 and DP3 configuration, along with the ARC receiver supervison window set to 180
seconds. For DP2 configuration, the supervison must be set to 30 minutes.
This product is in conformity with the Electromagnetic Compatibility Directive 2014/30/EU, the Low Voltage Directive 2014/35/EU, and
the RoHS3 Directive (EU) 2015/863.