Appendix 1: Reporting codes
Section #
Definition
Dialer
Direction*
Automatic Contact ID
Codes
SIA Auto Rep Codes**
[308]-[361]
Wireless Device Low Battery trouble/restore.
ZZZ= 601-616: wireless keypads
701-732: wireless keys
801-816: wireless Sirens
901-908: wireless repeaters
MA/R
E(3)84-ZZZ
R(3)84-ZZZ
XT-ZZZZ
XR-ZZZZ
[308]-[361]
Wireless Zone AC trouble/restore
MA/R
E(3)A1-ZZZ
R(3)A1-ZZZ
AT-ZZZZ
AR-ZZZZ
[308]-[361]
Wireless Device Fault/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
UT-ZZZZ
UJ-ZZZZ
[308]-[361]
Wireless Temperature and Flood Probe trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
KT-ZZZZ
KJ-ZZZZ
[308]-[361]
Freeze trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
ZT/ZJ-ZZZZ
[308]-[361]
Self Test Trouble/Restore*
Note:
To prevent a reporting code conflict do not
program PG9984 as zone 1.
MA/R
E (3)89-ZZZ
R (3)89-ZZZ
YX/YZ-ZZZZ
[308]-[361]
Carbon monoxide trouble/restore
MA/R
E(3)8A-ZZZ
R(3)8A-ZZZ
AT-(0901-0908)
AR-(0901-0908)
[308]-[361]
Wireless repeater 1-8 AC fail/restore
MA/R
E(3)A1-(901-908)
R(3)A1-(901-908)
UT/UJ-ZZZZ
[308]-[361]
RF jam/restore
MA/R
E(3)44-000
R(3)44-000
XQ-0000
XH-0000
[308]-[361]
Wireless repeater 1-8 RF jam/restore
MA/R
E(3)44-(901-908)
R(3)44-(901-908)
XQ-(0901-0908)
XH-(0901-0908)
Miscellaneous Alarms
[308]-[001]
Duress Alarm - Code entered at keypad
A/R
E(1)21-000
HA-0000
[308]-[001]
Opening After Alarm - Disarmed with alarm in memory
A/R
E(4)58-000
OR-0000
[308]-[001]
Recent Closing - Alarm occurs within two minutes of system
arming
A/R
E(4)59-UUU
CR-UUUU
[308]-[001]
Burglary Verified
A/R
E(1)39-000
BV-0000
[308]-[001]
Burglary Not Verified
A/R
E(3)78-000
BG-0000
[308]-[001]
HSM2108 Zone Expander Supervisory Alarm/restore
A/R
E(1)43-000
R(1)43-000
UA-0000 / UH-0000
[308]-[002]
Holdup Verified
A/R
E(1)29-000
HV-0000
[308]-[011]
Alarm Canceled before expiry of alarm cancellation timer
A/R
E(4)A6-UUU
OC-UUUU
[308]-[011]
PGM2 (Silent 24 Hour Input) -Aux Input Alarm/restore
A/R
E(1)46-992
R(1)46-992
UA-0992 / UH-0992
[308]-[011]
PGM2 (Audible 24 Hour Input) -Aux Input Alarm/restore
A/R
E(1)4A-992
R(1)4A-992
UA-0992 / UH-0992
[308]-[305]
PGM2 2-Wire Smoke Alarm/Restore
A/R
E(1)11-992
R(1)11-992
FA-0992 / FH-0992
Priority Alarm and Restoral Events
- 292 -