Section 6: Programming
047 - 24-Hour Emergency
Instant alarm when activated, audible alarm at default.
048 – 24-Hour Sprinkler
Instant alarm when activated, audible alarm at default.
049 – 4-Hour Flood
Instant alarm when activated, audible alarm at default.
051 – 24-Hour Latching Tamper
Instant alarm when activated, audible alarm at default. The alarm system cannot be armed until Installer Programming is entered after
the zone is restored.
052 – 24-Hour Non-Alarm
This zone is active at all times but does not cause an alarm. Zone attributes such as Zone Bypassing and Door Chime affect the
functionality of this zone. This zone type can also be assigned to a temperature sensor if indoor/outdoor temperature display is
required without temperature warnings or alarm conditions.
056 – 24 Hour High Temperature
This zone type is used with wireless temperature sensors and is activated when the temperature rises above a programmed
threshold (set in section [804][xxx][019-020]). Instant alarm when activated, audible alarm at default. This zone type generates an
alarm when the system is armed or disarmed.
Note:
This zone type cannot be used on hardwired zones. The temperature threshold includes a 3°C (5°F to 6°F) difference between
a given state and its restored condition. For example, an alarm at 6°C is restored at 3°C (high temperature) or 9°C (low temperature),
depending upon the zone type selected.
The zone type for wireless temperature sensors must be 24 Hour High/Low Temperature in order for the sensor to operate properly.
057 – 24-Hour Low Temperature
This zone type is used with wireless temperature sensors and is activated when the temperature drops below a programmed
threshold (set in section [804][xxx][019-020]). Instant alarm when activated, audible alarm at default. This zone type generates an
alarm when the system is armed or disarmed.
Note:
This zone type cannot be used on hardwired zones.
060 – 24-Hour Non-Latching Tamper
This zone is always active and reports a tamper condition with no audible alarm when opened or tamper/faulted.
061 - 24-Hour Masking
This zone is active 24 hours in either the armed or the disarmed state. This zone type does not generate an alarm, and does not log
in the Alarm Memory. This zone type generates a Masking Trouble on the system.
Note:
This zone operates in SEOL only.
066 – Momentary Keyswitch Arm
Often used with a keyswitch module*, turning the key alternately arms and disarms the system and silences the alarms. Tampers and
faults only initiate their respective trouble sequence. The keypad gives no indication when this zone type is activated.
Note:
With audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad. Using
the keyswitch during the first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the 90 second delay
starts). Activation of a keyswitch zone arms or disarms the system. Activation of this zone type is NOT logged nor is the Police code
transmitted. Bypassed zones of this type are not un-bypassed when the system is disarmed. When the zone is bypassed, a zone
bypass event buffer log and communication occurs immediately, NOT when the system is armed.
*Keyswitch module not for use in UL/ULC listed installations.
067 – Maintained Keyswitch Arm
Often used with a keyswitch module, turning the key (open state) arms the system. Turning the key back (restored state) disarms the
system. Tampers and faults only initiate their respective trouble sequence.
Note:
DO NOT use for wireless zones. Activation of the zone does not log or transmit the Police code. Bypassed zones of this type
are not un-bypassed when the system is disarmed. When the zone is bypassed, a zone bypass event buffer log and communication
occurs immediately, NOT when the system is armed.