Automatic Failure Detector and SubstitutorAFDS2 Model
Installation and Use Manual
© 2005 Bogen Communications, Inc.All rights reserved.Specifications subject to change without notice.54-5693-
1
0B 0507
Страница 1: ...Automatic Failure Detector and Substitutor AFDS2 Model Installation and Use Manual 2005 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5693 10B 0507 ...
Страница 2: ...installation Threshold is adjustable PACKAGE CONTENTS Automatic Failure Detector Substitutor unit Installation and Use Manual TECHNICAL SPECIFICATIONS Supervision Frequency 40 kHz Supervision Frequency Level 5mV to 50mV into 47k ohms Input Impedance 10k ohms Detector Input Signal 2V 40 kHz Detector Supervision Range 2 dB min to 12 db max Failure Indicators LEDs visual and tone module aural Control...
Страница 3: ...ector Sensitivity control R33 and the Standby Amp Detector Sensitivity control R2 fully clockwise If the DVM reads zero rotate the 40 kHz Oscillator Level control R21 clockwise until the Speaker Line switches to the main power amplifier 2 Set the audio source and main amplifier volume controls to their normal settings for maximum level of required program material Record the settings Use a tone ge...
Страница 4: ...n these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department All shipping charges in addition to parts and labor charges will be at the owner s expense All returns require a Return Authorization number 8 10 2004 WARRANTY 50 Spring Street Ramsey NJ 07446 Tel 201 934 8500 Fax 201 934 9832 www bogen com b Turn down the main power amplifier gain control while observi...