DESCRIPTION

The Bogen Model AFDS2,Automatic Failure Detector and Substitutor, is an electronic unit which continuously supervises the
operation of the main and standby power amplifiers in a sound system. Should the main amplifier’s output level drop by as
little as 2 dB, the AFDS2 substitutes the standby power amplifier.The changeover is nearly instantaneous with virtually no loss
of signal.

The AFDS2 injects a set level of a supersonic frequency (40 kHz) into the inputs of the main and standby power amplifiers
and continuously samples their outputs. If the 40 kHz level from either amplifier should fall below 2 dB*, a fault alert tone
will sound, indicating a failure. Front panel-mounted LEDs indicate whether the main amplifier or the standby amplifier failed.
The fault alert tone may be silenced by momentarily pressing the Silence button; however, the LED will stay on for the dura-
tion of the malfunction.

The AFDS2 may be used in either 25V or 70V systems. Booster output may be balanced or unbalanced; but, in a balanced sys-
tem, two accessory input isolation transformers (Model TL

1

00) are required.

The AFDS2 input impedance from the audio source is 

1

0,000 ohms. In applications where the pre-amplifier is located away

from the amplifier, the AFDS2 input can be converted to 600 ohms with the accessory WMT

1

A Line-Matching Transformer.

Screwdriver-adjustable controls for setting the oscillator level and the detector sensitivities are provided on the rear panel.

The AFDS2 operates from a 

1

20V AC/60 Hz or 

1

2V DC source. Line power consumption is 

1

5W. All connections are made

at screw terminals and RCA connectors on the rear chassis.The unit has a standard 

1

9-inch wide panel, is 3 

1

/2-inches high

and is suitable for either rack or cabinet installation.

* Threshold is adjustable

PACKAGE CONTENTS

• Automatic Failure Detector & Substitutor unit 
• Installation and Use Manual

TECHNICAL SPECIFICATIONS

Supervision Frequency:

40 kHz

Supervision Frequency Level:

5mV to 50mV into 47k ohms

Input Impedance:

1

0k ohms

Detector Input Signal:

2V @ 40 kHz

Detector Supervision Range:

2 dB (min.) to 

1

2 db (max.)

Failure Indicators:

LEDs (visual) and tone module (aural)

Controls:

Screwdriver-adjustable controls for oscillator level and detector sensitivity

Remote Annunciation:

Status terminal provides 

1

2V DC/500mA in the failure mode

Operating Temperatures:

1

4°F to 

1

49°F (-

1

0°C to 65°C)

Power Consumption:

1

20V AC,

1

5W, or 

1

2V DC @ 0.5A

Dimensions:

1

9" W x 3 

1

/2" H x 7-

1

/2" D

Weight:

8 lb.

Accessories:

Two TL

1

00 transformers for 25V or 70V balanced systems;WMT

1

A Line-Matching Transformer to match

the input from a 600-ohm balanced line

EQUIPMENT CONNECTIONS

AC Power Connections:

The AC line cord has a three-prong plug which should be plugged into a three-wire 

grounded

1

20V, 60 Hz outlet.This will automatically ground the chassis.

Auxiliary DC Power Connections:

The unit may be powered from the 

1

2V DC supply. The positive lead must be con-

nected to the EXT PWR terminal on the chassis and the negative lead to the GND terminal.

Input Connections:

The input impedance of the AFDS2 is 

1

0,000 ohms, accepting any unbalanced input capable of supply-

ing a signal at least 

1

0% greater than that needed to drive the power amplifiers (which must have an input impedance  of

1

0,000 ohms or greater). Provisions are incorporated for mounting an accessory Model WMT

1

A transformer to match the

input from a 600-ohm balanced line.

System Connections:

Single-conductor, low capacity shielded wire should be used for all input connections. These leads

should be as short as possible. The remaining connections can be made with either double-conductor shielded wire or
#20AWG hookup wire.

Note:

Input cables should be routed separately from output cables.

Содержание AFDS2

Страница 1: ...Automatic Failure Detector and Substitutor AFDS2 Model Installation and Use Manual 2005 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 5693 10B 0507 ...

Страница 2: ...installation Threshold is adjustable PACKAGE CONTENTS Automatic Failure Detector Substitutor unit Installation and Use Manual TECHNICAL SPECIFICATIONS Supervision Frequency 40 kHz Supervision Frequency Level 5mV to 50mV into 47k ohms Input Impedance 10k ohms Detector Input Signal 2V 40 kHz Detector Supervision Range 2 dB min to 12 db max Failure Indicators LEDs visual and tone module aural Control...

Страница 3: ...ector Sensitivity control R33 and the Standby Amp Detector Sensitivity control R2 fully clockwise If the DVM reads zero rotate the 40 kHz Oscillator Level control R21 clockwise until the Speaker Line switches to the main power amplifier 2 Set the audio source and main amplifier volume controls to their normal settings for maximum level of required program material Record the settings Use a tone ge...

Страница 4: ...n these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department All shipping charges in addition to parts and labor charges will be at the owner s expense All returns require a Return Authorization number 8 10 2004 WARRANTY 50 Spring Street Ramsey NJ 07446 Tel 201 934 8500 Fax 201 934 9832 www bogen com b Turn down the main power amplifier gain control while observi...

Отзывы: