Goodrive20-UL Series VFD
Function parameters
-98-
Function
code
Name
Description
Default Modify
Range: 0.0
–5000.0A
P17.08
Motor power
Display current power of the motor.
Setting range: -300.0%
–300.0%
(the rated current of the motor)
●
P17.09
Output
torque
Display the current output torque of the VFD.
Range: -250.0
–250.0%
●
P17.10
The motor
frequency
evaluation
Evaluate the motor rotor frequency on open
loop vector
Range: 0.00
– P00.03
●
P17.11
DC bus
voltage
Display current DC bus voltage of the VFD
Range: 0.0
–2000.0V
●
P17.12
Switch input
terminals
state
Display current Switch input terminals state
of the VFD
Range: 0000
–00FF
●
P17.13
Switch output
terminals
state
Display current Switch output terminals state
of the VFD
Range: 0000
–000F
●
P17.14
Digital
adjustment
Display the adjustment through the keypad
of the VFD.
Range: 0.00Hz
–P00.03
●
P17.15
Torque
reference
Display the torque reference, the percentage
to the current rated torque of the motor.
Setting range: -300.0%
–300.0% (of the rated
motor current)
●
P17.16
Linear speed
Display the current linear speed of the VFD.
Range: 0
–65535
●
P17.18
Counting
value
Display the current counting number of the
VFD.
Range: 0
–65535
●
P17.19
AI1 input
voltage
Display analog AI1 input signal
Range: 0.00
–10.00V
●
P17.20
AI2 input
voltage
Display analog AI2 input signal
Range: 0.00
–10.00V
●
P17.21
AI3 input
voltage
Display analog AI2 input signal
Range: -10.00
–10.00V
●
P17.22
HDI input
frequency
Display HDI input frequency
Range: 0.00
–50.00kHz
●
Содержание GD20-0R4G-2-UL