Goodrive20-UL Series VFD
Keypad operation
-25-
RUN/TUNE
FWD/REV LOCAL/REMOT
Hz
TRIP
A
V
RPM
%
RUN/TUNE
FWD/REV LOCAL/REMOT
TRIP
Hz
A
V
RUN/TUNE
FWD/REV LOCAL/REMOT
TRIP
Hz
A
V
RPM
%
RPM
%
Figure 4-2 Status display
4.3 Operations on the keypad
You can operate the VFD by using the keypad. For details about function code descriptions,
see the function code list.
4.3.1 Modifying VFD function codes
The VFD provides three levels of menus, including:
1. Function code group number (level-1 menu)
2. Function code number (level-2 menu)
3. Function code setting (level-3 menu)
Note:
When performing operations on the level-3 menu, you can press the PRG/ESC or
DATA/ENT key to return to the level-2 menu. If you press the DATA/ENT key, the set value of
the parameter is saved to the control board first, and then the level-2 menu is returned,
displaying the next function code. If you press the PRG/ESC key, the level-2 menu is returned
directly, without saving the set value of the parameter, and the current function code is
displayed.
If you enter the level-3 menu but the parameter does not have a digit blinking, the parameter
cannot be modified due to either of the following reasons:
1) It is read only. Read-only parameters include actual detection parameters and running
record parameters.
2) It cannot be modified in running state and can be modified only in stopped state.
Example: Change the value of P00.01 from 0 to 1.
The units place
is blinking
All digits are
blinking
Note: When setting the value, you can press and + to modify the value.
SHIFT
PRG
ESC
PRG
ESC
PRG
ESC
PRG
ESC
DATA
ENT
DATA
ENT
DATA
ENT
The units place
is blinking
The units place is
blinking
The units place is blinking
Figure 4-3 Modifying a parameter