P08.35
FDT2
retention
detection
value
Output frequency
FDT electrical level
FDT retention
Time
Time
Y, RO1, RO2
Setting range of P08.32: 0.00Hz
–P00.03 (Max.
output frequency)
Setting
range
of
P08.33
and
P08.35:
0.0
–100.0%
Setting range of P08.34: 0.00Hz
–P00.03 (Max.
output frequency)
5.0%
○
P08.36
Frequency
arrival
detection
range
When the output frequency is among the below
or above range of the set frequency, the
multi-function digital output terminal will output
the signal of "frequency arrival", see the
diagram below for detailed information:
Y
RO1, RO2
,
Output frequency
Set frequency
Detectionn range
Time
Time
Setting range: 0.00Hz
–P00.03 (Max. output
frequency)
0.00Hz
○
P08.37
Energy
Braking
enable
This parameter is used to control the internal
braking unit.
0: Disabled
1: Enabled
Note:
It is only applicable to VFD models that
are built in braking units.
0
○