Goodrive20-UL Series VFD
Function parameters
-38-
Function
code
Name
Description
Default Modify
P01.04
ACC
P13.14
P01.23
Constant
speed
In running
DEC
P0110
P13.14
P01.12
P01.09
t
Setting range of P01.09: 0.00Hz
–P00.03 (Max.
output frequency)
Setting range of P01.10: 0.00
–50.00s
Setting range of P01.11: 0.0
–100.0% (rated
current peak of the VFD)
Setting range of P01.12: 0.00
–50.00s
P01.13
FWD/REV
running
deadzone
time
This function code indicates the transition time
specified in P01.14 during FWD/REV rotation
switching. See the following figure.
Output frequency f
Forward
Reverse
Deadzone
time
Time t
Starting
frequency
Switch over after
zero frequency
Switch over after
starting frequency
Setting range: 0.0
–3600.0s
0.0s
○
P01.14
Switching
between
FWD/REV
rotation
Set the threshold point of the VFD:
0: Switch after zero frequency
1: Switch after the starting frequency
2: Switch after the speed reach P01.15 and
delay for P01.24
1
◎
P01.15
Stopping
speed
0.00
–100.00Hz
0.50Hz
◎
P01.16
Detection
of
stopping
speed
0: Detect at the setting speed
1: Detect at the feedback speed (valid only for
vector control)
1
◎
Содержание GD20-0R4G-2-UL
Страница 1: ......
Страница 160: ...201905 V1 6 6 6 0 0 1 0 0 4 3 0 66001 00392...