Goodrive20-UL Series VFD
Fault tracking
-111-
Fault
code
Fault type
Possible cause
Solutions
upload error
good connection or
offline;
The keypad cable is
too long and there is
strong interference;
Part of the
communication
circuits of the keypad
or main board have
fault.
environment and
eliminate the
interference source;
Change hardware and
ask for maintenance
service;
Change hardware and
ask for maintenance
service.
DNE
[28] Parameter
download error
The keypad is not in
good connection or
offline;
The keypad cable is
too long and there is
strong interference;
Data storage error in
keypad
Check the
environment and
eliminate the
interference source;
Change hardware and
ask for maintenance
service;
Backup data in the
keypad again
ETH1
[32] To-ground
short-circuit fault 1
The output of the VFD
is short circuited with
the ground.
There is fault in the
current detection
circuit.
There is a great
difference between
the actual motorpower
setting and the VFD
power.
Check if the
connection of the
motor is normal or not.
Change the hall.
Change the main
control panel.
Reset the correct
motor parameter.
ETH2
[33] To-ground
short-circuit fault 2
dEu
[34] Speed
deviation
fault
Load is too heavy, or
stall occurred.
Check the load to
ensure it is proper,
increase the detection
time.
Check whether control
parameters are set
properly.
STo
[35] Mal-adjustment
fault
Control parameters of
synchronous motor
Check the load to
ensure it is proper.
Содержание GD20-0R4G-2-UL