Goodrive20-UL Series VFD
Function parameters
-40-
Function
code
Name
Description
Default Modify
(valid
when
frequency
lower limit
greater
than 0)
P01.20
Wake
–up
–from-sle
ep delay
This
function
code
determines
the
wake-up-from-sleep delay time. When the
running frequency of the VFD is lower than the
lower limit, the VFD becomes standby.
When the set frequency exceeds the lower limit
one again and it lasts for the time set by P01.20,
the VFD runs automatically.
Set frequency curve:
Running frequency curve:
Run
Sleep
t2
t1
Run
Frequency
lower limit f0
Frequency f
Time t
Coast to
stop
t1 < P01.20, the VFD does not run
t1+t2
≥
P01.20, the VFD runs
Setting
range:
0.0
–3600.0s (valid when
P01.19=2)
0.0s
○
P01.21
Restart
after
power off
This function can enable the VFD start or not
after the power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the VFD
will run automatically after waiting for the time
defined by P01.22.
0
○
P01.22
The
waiting
time of
restart
after
power off
The function determines the waiting time before
the automatic running of the VFD when
powering off and then powering on.
Output frequency
Running
Power off
Power on
Running
t
t1
t2
t1=P01.22
t2=P01.23
1.0s
○
Содержание GD20-0R4G-2-UL
Страница 1: ......
Страница 160: ...201905 V1 6 6 6 0 0 1 0 0 4 3 0 66001 00392...