MPC 2000 ID / MP 3000, Super Freezer "Error message list"
#
Error Message
Controller Action
1
Power Error, Check 20A Fuses
Indicates:
• One or more phases are missing
• Compressor is able to draw amps on all
phases while heater lacks amps on one or
more phases
• Controller activates alarm 18
• Controller will try to restart unit after 60
minutes.
10
Cond probe found, please change type
Indicates:
• Controller is set for CRR40 DF and start-up is
initiated on a KVQ/CRR PS, CSR PS or CSR
Magnum unit. Correct by turning Un it On/Off
switch Off. Then set controller software switch
to correct position. See controller software
selection.
• None. On CRR40 DF units, condenser
sensor input must be left open.
11
Scroll Compressor, High Temperature
Indicates:
• Compressor stops because discharge
temperature is above 140 c (284 F). Message
remains in display until discharge temperature
decreases to normal.
• Controller clears message after
compressor start up.
12
Scroll Compressor, Low Pressure
Indicates:
• Low pressure cutout switch is open.
• Possible causes include stepper motor valve
will not open, warm gas bypass valve wil not
open, low refrigeratn charge, defective low
pressure cutout switch, open circuit, etc.
• Controller activates Alarm 31 after 5
minutes.
• Controller clears message after
compressor start up.
13
R134a Compressor, High Temperature
Indicates:
• Compressor stops because discharge
temperature is above 130 C (266 F).
Compressor remains Off until discharge
temperature decreases to 90 C (194 F)
• Controller actrivates Alarm 56.
• Controller clears message when
compressor temperature decreases below
130 C (266 F). However, compressor
remains off until discharge temperature
decreases to 90 C (194 F).
14
Evaporator High Temperature Switch Open
Indicates:
• Controller disables electric heaters due to
open high temperature switch circuit.
• Possible causes include evaporator
temperature over 54 C (130 F), defective
heater, defective evaporator overheat switch,
open circuit, etc.
• Controller clears message when high
temperature switch closes.
• NO alarm is set until Controller determines
that heater current draw is too high (alarm
10), unit current draw is too high (alarm
36), or defrost time is too long (alarm 20).
15
R134a Compressor Fault
• Feedback from 134a Compressor is Missing
• Check to be certain 134a compressor is
running
• Check continuity through 134a auxiliary
contactor on Main Relay Board plug J12.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...