![Ingersoll-Rand Thermo King CRR DF MPC2000 Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/ingersoll-rand/thermo-king-crr-df-mpc2000/thermo-king-crr-df-mpc2000_maintenance-manual_2060249069.webp)
Microprocessor Controller
68
•
ACKNOWLEDGE: An alarm code has been viewed and acknowledged in the alarm list. The Alarm
LED remains ON but does not flash.
•
If the alarm condition is corrected, the Alarm LED will turn OFF and the alarm code disappears
from the alarm list.
Viewing the Alarm List menu:
With the unit On/Off switch ON and the LCD display showing the standard display (setpoint):
1. Press F2 key to directly enter the Alarms menu. The first alarm code number, alarm state and alarm
description appears in LCD display.
NOTE: Alarm codes are displayed in sequential order, not in the order of occurrence.
2. Write down the first alarm code. Then press F2 key to view the next alarm code when more than one
alarm code has been recorded.
3. Repeat step 4 until all alarm codes have been recorded. To scroll backward to return to a previous
alarm code, press F3 key.
4. To clear all alarm codes from the current display list and turn off the Alarm LED, all problems must
be corrected and the alarm code “acknowledged” in the Alarm List menu.
NOTE: To acknowledge an alarm, press F4 while the alarm code appears on the screen. The alarm
state will change from ACTIVE or NOT ACTIVE to ACKNOWLEDGE.
NOTE: If no key is pressed for 30 seconds, the controller returns to the previous menu level or the
LCD Standard Display.
Commands Menu
The Commands menu displays a list of tasks that can be activated. The following commands are
available:
•
Defrost: Manual defrost can be initiated. When command is activated, LCD message display will
show ACTIVATED, NOT ACTIVATED (evaporator temperature above 18 C [50 F]) or ALREADY
ACTIVATED (defrost in progress).
•
PTI (Pretrip) Test: Controller automatically completes a test of individual components and checks
unit refrigeration capacity, heating capacity, temperature control and defrost. See “PTI (Pretrip)
Test” in this chapter for test details.
•
Manual Function Test: Controller tests individual components selected by the technician for
diagnosis. LCD display will show expected and actual current of the component being tested.
Viewing the Commands menu:
With the unit On/Off switch ON and the LCD display showing the standard display (setpoint):
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll through Main Menu until “COMMANDS” appears in LCD display.
3. Press F4 key to access the Commands menu. The first command in the submenu (Defrost) appears in
the LCD display.
CAUTION: The PTI test should only be performed on an empty container!
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...