1. Press the F3 key to enter the Main Menu. Press F2 key to scroll through Main Menu until “MISC.
FUNCTIONS” appears in LCD display.
2. Press F4 key to access the Misc. Functions menu. The first command in the submenu appears in the
LCD display: Date Time.
3. Press F2 or F3 key to scroll to the desired function:
•
Date Time
•
C/F Mode
•
Cargo Data
•
Program Version
•
Run Time
4. Press F4 key to access the function selected.
Setting the Date and Time
1. Press the F3 key to entering Main Menu. Press F2 key to scroll to “MISC. FUNCTIONS”.
2. Press F4 key to access the Misc. Functions menu. “Date Time” appears in the LCD display.
3. Press F4 key to access the Date Time screen. Date Time screen appears with cursor in the Time menu
line. Display shows time in “HH.MM.SS” where H = hour, M = minute and S = second.
4. To enter a new time, press F4 key with cursor in Time menu line. An Enter Arrow appears in the menu
line and the previous time disappears.
5. Enter new time in “HH.MM.SS” format. Decimal points must be included in the entry between the
hour, minute and second.
NOTE: To scroll backward in the Time or Date menu line, press and hold the F4 key, then press F3
key. Press F1 key to return keyboard to “numerical” entry before typing again.
6. With the correct time entered in the menu line, press F4 key. Then press EXIT key to enter time in
controller memory. Cursor stops blinking and new time appears in display.
7. To enter a new date, press F3 key to move cursor to Date menu line. Display shows date in and date in
“YY.MM.DD” where Y = year, M = month and D = day.
8. Press F4 key with cursor in Date menu line. An Enter Arrow appears in the menu line and the
previous date disappears.
9. Enter new date in “YY.MM.DD” where Y = year, M = month and D = day. Decimal points must be
included in the entry between the year, month and day.
10. With the correct date entered in the menu line, press F4 key. Then press EXIT key to enter date in
controller memory. Cursor stops blinking and new date appears in the display.
11. Press ESC key to exit the Date Time screen.
Changing the Temperature Display Value (C/F)
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll to “MISC. FUNCTIONS”.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...