Unit Description
General Description
Model CRR DF units are all-electric, single-piece, refrigeration units with bottom air supply. Each unit is
designed for long distance, shipboard or overland transport of deep frozen or frozen cargoes. Each unit
mounts in the front wall of the container. Fork lift pockets are provided for installation and removal of the
unit.
The frame and bulkhead panels are constructed of aluminum and are treated to resist corrosion. A hinged,
removable vaporator compartment door provides easy service access. All operating components except
the evaporator coil and buffer receiver tanks can be replaced from the front of the unit.
The unit is equipped with an 18.3 m (60 ft) power cable for operation on 460-380V/3 Ph/60-50 Hz power.
For operation on 460-380V/3 Ph/60-50 Hz power, plug the 460-380Vpower cable into the proper power
supply.
Each unit is equipped with 460-380V/3 Ph/60-50 Hz electric motors. An automatic phase correction
system provides the proper electrical phase sequence for condenser fan and evaporator fan motor
operation. Unit power cable is stored below the control box in the condenser section.
CRR DF MPC2000 units feature MPC2000 microprocessor controller and a MPC2000 Datalogger. CRR
DF MP3000 units feature MP3000 microprocessor controller and a MP3000 Datalogger. CRR
DFMPC2000ID units feature a MPC2000ID microprocessor controller with integral datalogger.
Additional features include three evaporator fans; USDA Cold Treatment Temperature Recording; and a
Remote Monitoring Modem (RMM). For additional unit feature information, see “CRR DF Model
Features” on page v of the Introduction.
Cascade Refrigeration System
The CRR DF unit uses a basic cascade refrigeration system to achieve to frozen and deep frozen cargo
temperatures between -10 C and -60 C (+14 F and -76 F). The CRR DF cascade refrigeration system
design allows shippers to economically carry cargo at deep frozen temperatures using proven, reliable
transport refrigeration system technology.
The CRR DF cascade systems consists of two separate, single-stage refrigeration systems with different
refrigerants.One system is a low temperature stage system that uses a hermetic scroll compressor and
R-23 refrigerant. The evaporator of the low temperature stage system cools the cargo air, achieving cargo
temperatures down to -60 C (-76 F).
The second system is a high temperature stage system that uses a semi-hermetic reciprocating compressor
and R-134a refrigerant. The evaporator of the high temperature stage system cools the condenser of the
low temperature stage system through a special plate heat exchanger. The condenser of the high
temperature stage system then transfers the cargo heat to the ambient air.
R-134a Semi-hermetic Reciprocating Compressor
The R-134a high temperature stage circuit features a semi-hermetic reciprocating compressor with forced
feed lubrication system, ambient compensated internal overload protection and high temperature
protection.
R-23 Hermetic Scroll Compressor
The R-23 low temperature stage circuit features a hermetic scroll compressor (one stationary and one
orbiting member) with ambient compensated internal overload protection and high temperature
protection.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...