Microprocessor Controller
67
•
Voltage 1 (Main Power Supply)
•
Voltage 2 (Main Power Supply)
•
Voltage 3 (Main Power Supply)
•
Frequency (Main Power Supply)
•
Zero Current
•
Current Phase 1 (Main Power Supply)
•
Current Phase 2 (Main Power Supply)
•
Current Phase 3 (Main Power Supply)
NOTE: Press the “5” key to lock a Data screen in the LCD display for 5 minutes. Press any key to
unlock the display.
NOTE: Controller returns to previous menu level or LCD Standard Display after 30 seconds.
Alarm List Menu
The Alarm List menu displays alarm codes. If the Alarm LED is ON or flashing ON and OFF, enter the
ALARM LIST to view the alarm code(s).
Alarm Types
There are three types of alarms:
Shutdown Alarm (Level 1):
Alarm LED flashes and unit stops. Shutdown alarms indicate the unit has been
stopped to prevent damage to the unit or cargo. The condition must be corrected before restarting the unit.
Alarm code 56 (Compressor Temperature Too High) is a shutdown alarm.
Check Alarm (Level 2):
Alarm LED flashes until alarm is acknowledged. Check alarms indicate corrective
action should be taken before a problem becomes severe. Alarm codes 00-17, 18, 19, 20, 22, 23, 34, 35,
43, 52, 58, 112 are Check alarms.
Log Alarm (Level 3):
Alarm is recorded in datalogger only (inspect event log). Alarm LED does not flash
or turn on. Alarm codes 59, 97, 98 are Log alarms.
Alarm Code States
There are three alarm code states for Shutdown and Check alarms:
•
NOT ACTIVE: An alarm condition has occurred but no longer exists in the unit. Not Active means
the condition was corrected and did not recur for 1 hour; or the unit On/Off switch was turned OFF
and then ON.
•
When a NOT ACTIVE alarm code is acknowledged (F4 key pressed while alarm code appears in
LCD display), the Alarm LED will turn OFF and the alarm code disappears from the alarm list.
•
ACTIVE: An alarm condition has occurred and continues to exist in the unit; or the alarm condition
occurred within the past 1 hour but does not currently exist in the unit.
•
If the alarm condition currently exists in the unit and the alarm code is acknowledged, the Alarm
LED will stop flashing but remain ON. The alarm code state will change to ACKNOWLEDGE in
the alarm list.
•
If the alarm condition no longer exists in the unit and the alarm code is acknowledged, the Alarm
LED will turn OFF and the alarm code disappears from the alarm list.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...