![Ingersoll-Rand Thermo King CRR DF MPC2000 Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/ingersoll-rand/thermo-king-crr-df-mpc2000/thermo-king-crr-df-mpc2000_maintenance-manual_2060249065.webp)
Microprocessor Controller
64
•
A Timed Defrost always starts at 1 minute past the hour immediately following a defrost timer request
for defrost. For example, if the defrost timer requests a defrost cycle at 7:35, the defrost cycle will
start at 8:01. The datalogger will record a Defrost event for each log interval in which a Defrost cycle
is pending or active (i.e. both the 8:00 and 9:00 data logs on 1 hour logging interval).
•
On Frozen Loads, the initial time interval is 12 hours. Six (6) hours are added to the time interval
each time a timed defrost interval occurs without a demand defrost in between. Maximum
accumulated time interval is 36 hours. Time interval resets to 12 hours when setpoint is changed
more than 5 C (9 F); or if the unit is turned OFF for 12 hours.
When the defrost mode is initiated:
•
The controller de-energizes both the R-134a and R-23 compressor contactors, the condenser fan
contactor and the evaporator fan contactors; stopping the compressors, condenser fan and evaporator
fans.
•
When the compressors stop, the controller turns ON the Defrost LED, Heat LED and energizes the
heater contactor, turning on the electric heaters.
The controller terminates the defrost mode when:
•
Frozen mode: Evaporator coil sensor temperature reaches 18 C (65 F).
•
Time/temperature function: If the evaporator coil sensor exceeds 8 C (47 F) for 15 minutes, the
controller terminates defrost.
•
Interval timer: Controller terminates defrost 90 minutes after initiation if the coil sensor temperature
has not terminated defrost (120 minutes if power supply is less than 55H). Alarm code 20 will be
generated if this occurs.
•
When the controller terminates Defrost, the heater contactor is de-energized. The controller starts the
condenser fan and the R-134a compressor. After 30 seconds, the controller starts the R-23 compressor
and the evaporator fans to minimize heat energy release into the container.
Changing the Setpoint
To change the controller setpoint, turn the unit On/Off switch ON. With the standard LCD
message display showing on the controller (i.e. setpoint temperature):
1. Press the SETPOINT key. The DATA menu appears with the cursor flashing in the “TEMP SETP”
line.
2. Press the F4 key. An Enter Arrow appears in the menu line and the current setpoint disappears.
3. Enter (type) the new setpoint in the LCD display using the general purpose keypad. To enter a minus
setpoint, press the EXIT (±) key first. The cursor moves to the right of the screen as each key entry is
acknowledged and displayed.
NOTE: Always check that the setpoint entered in the LCD display is correct before proceeding.
4. Press and hold the F4 key until the cursor stops flashing. The new setpoint is recorded in the
controller and appears briefly in the LED display.
NOTE: When the setpoint appears in the LED display, both the Return and Supply LEDs are lit.
NOTE: If the F4 key is not pressed within 30 seconds, the controller will default (return) to the
previous setpoint. If this occurs, repeat steps 1 through 4.
5. Controller returns to the standard LED Display (shows return temperature) within 5 seconds and the
standard LCD display (showing new setpoint) within 60 seconds.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...