Unit Description
29
REFCON Remote Monitoring Modem (RMM)
A REFCON remote monitoring modem is provided to permit remote monitoring via the power cable.
High speed transmission reads all controller information. Data can also be retrieved from the datalogger
via high speed transmission.
Operating Modes
NOTE: See Microprocessor Controller chapter for complete sequence of operation.
A sequence start of the required loads occurs during initial start-up of the unit and when a control mode
shift requires the compressors to start. As the controller relays and unit loads energize, the controller LCD
display shows the setpoint temperature. The controller LED display shows the controlling (return) air
sensor temperature.
Frozen Loads
Temperature control by the controller is based on the return air sensor temperature. The evaporator fans
operate continuously on low speed (except during defrost).
•
Cooling until return air temperature decreases to 1 C (1.8 F) below setpoint. Minimum 15 minute
compressor ON (running) time and 10 minute compressor OFF time prevents rapid cycling between
Cool and Null modes.
•
Null until return air temperature increases to 1 C (1.8 F) above setpoint. Both compressors and the
condenser fan stop while the evaporator fans operate on low speed during the null mode.
•
Defrost: Resistance heaters turn ON during defrost while the evaporator fans stop.
A Demand Defrost can be initiated by the controller when the temperature difference between the return
air sensor and setpoint increases to a pre-set value and a minimum of 6 hours of compressor ON (running)
time have elapsed since the previous defrost.
A Defrost Timer also initiates defrost every 12 hours. During extended unit operation, timed defrost
intervals increase 6 hours each time a timed defrost occurs without a demand defrost in between.
Maximum time interval is 36 hours. The Defrost Timer resets if the unit is OFF more than 12 hours or the
setpoint is changed more than 5 C (9 F).
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...