Operating Instructions
48
•
Heat (On during defrost)
•
Defrost
•
In-Range (Temperature)
•
Alarm
The In-range LED illuminates when the controlling air sensor temperature is less than 3.0 C (5.4 F) above
setpoint (standard). The controller maintains the in-range signal during defrost and after defrost for 60
minutes.
LED Display:
Large red LED display shows current control temperature during normal operation. LED
display also shows current test state during a Pretrip (PTI) or Function test.
LCD Display:
A 4-line LCD message display shows setpoint during normal operation. LCD display also
shows controller menu and unit operation information when special keys are pressed.
Other
Evaporator Overheat Switch:
A temperature switch near the evaporator coil opens to de-energize the
heater contactor if the evaporator temperature reaches 54 C (130 F) during Defrost. The switch closes
(resets) when the evaporator temperature decreases to 32 C (90 F).
R-134a Refrigeration System Controls, Instruments and Protection
Devices
Compressor Discharge Line Temperature Sensor:
The controller uses the compressor discharge line
temperature sensor to protect the compressor from excessively high operating temperatures. If the
discharge gas temperature rises above 130 C (266 F):
•
Unit stops immediately; controller activates Alarm LED and records Alarm 56, Compressor
Temperature Too High.
•
Controller will restart the unit when the sensor temperature is below 90 C (194 F).
High Pressure Cutout (HPCO) Switch:
If the compressor discharge pressure rises above 2410 ± 68 kPa,
24.1 ± 0.68 bar, 350 ± 10 psig, the high pressure cutout opens to interrupt the ground circuit to the
compressor contactor:
•
R-134a compressor STOPS immediately.
•
Evaporator and condenser fans continue normal operation.
•
R-23 compressor stops.
•
R-134a compressor will restart when the overload condition is corrected (switch closes) as long as
power is available. The high pressure switch resets (closes) when the pressure drops to 1640 ± 68 kPa,
16.4 ± 0.68 bar, 238 ± 10 psig.
•
R-23 compressor will restart 30 seconds after R-134a compressor restarts.
Suction Pressure Gauge:
A suction pressure gauge indicates the refrigerant pressure in the suction line
returning to the compressor.
Discharge Pressure Gauge:
A discharge pressure gauge indicates the refrigerant pressure in the discharge
line leaving the compressor.
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...