Microprocessor Controller
74
Configuration Menu
The Configuration menu displays a list of functions that identifies unit operating features and current
settings. The following functions are available:
MP-3000 Configuration List, DF Units
Viewing or Setting Functions in the Misc. Functions menu:
With the unit On/Off switch ON and the LCD display showing the standard display (setpoint):
1. Press the F3 key to enter the Main Menu.
2. Press F2 key to scroll through Main Menu until “CONFIGURATIONS” appears in LCD display.
3. Press F4 key to access the Configurations screen. Configurations screen appears with cursor in the
In-Range menu line.
4. Press F3 key to scroll cursor to view or reset the desired function:
•
In-Range: Sets the temperature value for the controller’s In-range LED and datalogger functions
(factory default = 1.5 C [2.7 F]). Enter a value from 0.5 to 5.0 C (0.9 to 8.9 F).
•
Container ID: Sets the container identification number. Enter up to 11 characters (numbers or
letters).
•
Contrast: Controller automatically regulates black and white contrast value on LCD display
according to display temperature. Standard setting is 45. Resetting this value is not recommended.
•
Zero Current: View display ON or OFF value (factory default = ON). However, no errors occur if
a Zero Current transformer is not installed and configuration is set to ON.
5. To set a new Configuration screen value:
a. Press F4 key with cursor in the desired menu line. The Password screen appears.
b. Press F2 key, “A” key (password is “A”), F4 key and then EXIT key. An Enter Arrow appears in
the hourmeter line.
c. Use the general purpose keypad to enter the desired value; or press the F3 key to toggle the value
to the desired setting.
d. When the entry is complete, press and hold the F4 key until the cursor stops flashing. The new
value appears in the menu line.
Text
Description
Default
Range
IN RANGE
In range limit
1,5°C
0,5°C - 5°C
CONT ID
Container Id
LOSUxxxxxxx
Must be valid
CONTRAST
The LCD contrast
45
0 - 255
LANGUAGE
The used language
GB
GB
ZERO CURR
Zero current measuring
On
On/Off
USDA TYPE
Usda probe set up
3 PT100
3 PT100 / 3 THERM / 4 THERM
CHART R.
Chart recorder option
Not Present
Not Present/ +/-25C 31dy
AUTO CONFIG
Auto configuration wanted
On
On/Off
UNIT #
Reefer unit identification
---------
9x any char
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...