Operating Instructions
52
•
Enter minus sign first by pressing EXIT key. Then press numeric keys to enter new setpoint.
•
With correct setpoint in display, press and hold F4 key until cursor stops flashing. Controller
places new setpoint in controller memory and shows new setpoint in LCD display.
NOTE: New setpoint must be between -10 C and -60 C (14 F and -76 F) or controller will return to
the previous setpoint display.
NOTE: If the F4 key is not pressed within 30 seconds, the controller will default (return) to the
previous setpoint. If this occurs, repeat step 3.
4. Check the direction of the condenser airflow (see “Condenser Fan and Evaporator Fan Rotation” in
the Electrical Maintenance chapter of this manual).
5. Check direction of evaporator airflow (see “Condenser Fan and Evaporator Fan Rotation” in
Electrical Maintenance chapter of this manual).
6. Allow the unit to operate one-half hour before loading. This will remove residual container heat and
moisture, and pre-cool the container interior.
7. Perform a Pretrip (PTI) Test and check unit modes while the unit pre-cools:
NOTE: Correct all existing alarm conditions and clear the alarm codes before performing a PTI test.
The controller will automatically clear all existing alarms before beginning the PTI test.
•
Press F2 key to enter Main Menu.
•
Press F2 or F3 key to scroll up or down in menu to “COMMANDS”.
•
Press F4 key to access COMMANDS menu.
•
Press F2 or F3 key to scroll up or down to “PTI”.
•
Press F4 to start the PTI (Pretrip) Test.
•
The controller then performs the Pretrip Test.
•
Observe the unit for proper operation and functions during pretrip test.
•
LCD display shows PTI Test currently being performed. PTI test ends automatically. Press any
key on the controller to return the unit to normal operation.
•
If an operating problem occurs during the Pretrip Test, the Alarm LED will turn ON and FLASH.
An “E” may also appear in the right side of the LED display. View and correct any alarm
conditions. Then clear (acknowledge) the Alarm Code(s) and repeat the PTI Test.
NOTE: Clear the Alarm codes ONLY after the alarm codes are documented and problems repaired.
A permanent record of the alarm codes remains stored in the datalogger memory for retrieval via
DRU-II or SmartSponge handheld data retriever.
8. Stop the unit by moving the On/Off switch to the OFF position.
Loading Procedure
1. Make sure the Unit On/Off switch is OFF before opening the container doors. (The unit may be
operating when loading the container from a warehouse with door seals.)
2. Spot check and record load temperature while loading. Especially note any off-temperature product.
CAUTION: The PTI test should only be performed on an empty container!
Содержание Thermo King CRR DF MPC2000
Страница 5: ...4 ...
Страница 11: ...List of Figures 10 ...
Страница 13: ...Introduction 12 ...
Страница 19: ...Safety Precautions 18 ...
Страница 21: ...Service Guide 20 ...
Страница 47: ...Unit Description 46 ...
Страница 97: ...Microprocessor Controller 96 ...
Страница 101: ...Electrical Maintenance 100 ...
Страница 141: ...Structural Accessory Maintenance 140 ...
Страница 147: ...Refrigeration System Diagnosis 146 ...
Страница 149: ...Electrical Refrigeration and Controller Menu Flow Diagrams 148 This page intentionally left blank ...
Страница 150: ...149 CRR DF MPC2000 Controller Diagram ...
Страница 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Страница 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Страница 153: ...152 CRR DF MP3000A Controller Diagram ...
Страница 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Страница 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Страница 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Страница 159: ...158 CRR DF Off Cycle Standby Flow and Pressure Diagram Page 2 of 2 CRR DF Off Cycle Standby Flow and Pressure Diagram ...
Страница 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Страница 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...