Chapter 5 List of Parameters
5.1 I/O Parameters
160
I/O Parameters
No.
Parameter name
Default
value
(Reference)
Input
range
Unit
Remarks
56 Output function selection
310
Common
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 310 (Internal DIO) is input to
input port No. 003 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 309, “Physical input port number
for input function selection 310.”
57 Output function selection
311
Common
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 311 (Internal DIO) is input to
input port No. 004 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 310, “Physical input port number
for input function selection 311.”
58 Output function selection
312
Common
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 312 (Internal DIO) is input to
input port No. 005 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 311, “Physical input port number
for input function selection 312.”
59 Output function selection
313
Common
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 313 (Internal DIO) is input to
input port No. 006 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 312, “Physical input port number
for input function selection 313.”
Pulse
Motor
Type
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 314 (Internal DIO) is input to
input port No. 014 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 313, “Physical input port number
for input function selection 314.”
60 Output function selection
314
AC Servo
Motor
Type
0
0 ~ 5
0: General-purpose output
1:
At absolute data backup battery voltage drop warning
level or below
(
OR check on all axes. Latched to power-on
reset/software reset after error level detected.
)
* The condition of output port No. 314 (Internal DIO) is input to
input port No. 014 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 313, “Physical input port number
for input function selection 314.”
61 Output function selection
315
Common
0
0 ~ 5
0: General-purpose output
* The condition of output port No. 315 (Internal DIO) is input to
input port No. 015 (Internal DIO).
(Port number is set in the parameter at delivery)
Note: The port number assigned to this function can be changed
using I/O Parameter No. 314, “Physical input port number
for input function selection 315.”
62
Physical input port
number
for axis-1 brake forced
release
Common
0
0 ~ 299
Forcibly unlock the brake when the applicable port is ON
(Be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
63
Physical input port
number
for axis-2 brake forced
release
Common
0
0 ~ 299
Forcibly unlock the brake when the applicable port is ON
(Be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
64
Physical input port
number
for axis-3 brake forced
release
Common
0
0 ~ 299
Forcibly unlock the brake when the applicable port is ON
(Be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
65
Physical input port
number
for axis-4 brake forced
release
Common
0
0 ~ 299
Forcibly unlock the brake when the applicable port is ON
(Be aware of a falling load).
* Invalid if “0” is set (Invalid if input port No. 0 is specified)
66 (For extension)
Common
0
67 (For extension)
Common
0
68 (For extension)
Common
0
69 (For extension)
Common
0
Содержание TTA Series
Страница 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Страница 2: ......
Страница 4: ......
Страница 23: ...13 ...
Страница 24: ...14 ...
Страница 25: ...15 ...
Страница 42: ...32 ...
Страница 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Страница 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Страница 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Страница 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Страница 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Страница 370: ...Chapter 10 Life 360 ...
Страница 377: ......