Chapter 1 Specifications Check
1.3 Electrical Specifications
60
1.3
Electrical Specifications
Item
Description
Power supply Voltage
AC100 to 230V ±10%
Power Supply Frequency Range
50/60Hz ±5%
Pulse Motor
2.9A/1.2A (AC100/230V, when rated load)
Current
Consumption
Servo Motor
2-axis type: 2.9A/1.2A (AC100/230V, when rated load)
3-axis, 4-axis type: 5.8A/2.4A (AC100/230V, when rated load)
Service Power Output (For I/O)
24V DC ±10% MAX. 1A
Pulse Motor
At 100V AC: 15A Typ.
At 200V AC: 30A Typ.
(Surrounding temperature 25
℃
, No repeating of AC ON/OFF)
Rush Current
Servo Motor
At 100V AC: 30A Typ.
At 200V AC: 60A Typ.
(Surrounding temperature 25
℃
, No repeating of AC ON/OFF)
Transient Power Cutoff Durability
20ms
Voltage
DC24V (Built-in Power Source)
Rated
Current
2-axis type: 4A
3-axis type: 6A
4-axis type: 8A
Pulse
Motor
Peak Max.
DC Current
Output
2-axis type: 8A
3-axis type: 12A
4-axis type: 16A
Voltage
DC24V
Rated
Current
2-axis type: MPO_A 7A, MPO_B 0A
3-axis type: MPO_A 7A, MPO_B 4A
4-axis type: MPO_A 7A, MPO_B 8A
Motor Drive
Power Supply
Line
(Between MPI
and MPO)
Servo
Motor
Peak Max.
DC Current
Output
2-axis type: MPO_A 16A, MPO_B 0A
3-axis type: MPO_A 16A, MPO_B 8A
4-axis type: MPO_A 16A, MPO_B 16A
Emergency Stop Input (EMGIN),
Enable Input (ENBIN)
DC24V/10mA or less
Contact Output (EMGS1+/-,
EMGS2+/-, ENBS1+/-, ENBS2+/-)
DC30V/0.5A or less
Motor Control System
Weak field-magnet vector control
Serial
Communication
Interface
(SIO Port)
Teaching Port
Connector dedicated for teaching tool
(Serial communication protocol (format B)
Connector: D-sub25-pin, USB B connector
Baud rate: 9.6
、
19.2
、
38.4
、
57.6
、
76.8
、
115.2kbps
Max. cable length: 10m (RS232C), 5m (USB)
PIO Type
Signal I/O dedicated for 24V DC (Selected from NPN/PNP)
• • • 16 points of input, 16 points of output
When extension DIO mounted: 48 points of input, 48 points of output
Cable length Max.100m
External
Interface
Field Network Type DeviceNet, CC-Link, PROFIBUS-DP, EtherNet/IP, EtherCAT, RS232C, RS485
Data Setting and Input
PC software or teaching pendant
Data Retention Memory
Position data and parameters are saved in the nonvolatile memory
Number of Programs
255
Number of Program Steps
9999
Number of Multitask Programs
16
Number of Positions
30000 points
(Note) 10000 points for system memory backup
LED Display
(Allocated on Front Panel)
RDY (Green): PIO program operation available
ALM (Orange): Error in operation cancel level or more generated
EMG (Red): In emergency stop
HPS (Green): Home-return operation completed on all axes
CKE (Orange): System lock error
Z-Axis Electromagnetic Brake
Compulsory Release Switch
(Allocated on Front Panel)
Switchover of NOM (normal) / BK RLS (compulsory release)
Insulation Resistance
Between secondary – FG 500V DC 10M
or more
Содержание TTA Series
Страница 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Страница 2: ......
Страница 4: ......
Страница 23: ...13 ...
Страница 24: ...14 ...
Страница 25: ...15 ...
Страница 42: ...32 ...
Страница 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Страница 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Страница 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Страница 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Страница 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Страница 370: ...Chapter 10 Life 360 ...
Страница 377: ......