Chapter 5 List of Parameters
5.3
Axis-Specific Parameters
184
Axis-Specific Parameters
No.
Parameter name
Default
value
(Reference)
Input range
Unit
Remarks
84 System reservation
Common
0
0 ~ 100
mm/sec
85 Home-return
acceleration/deceleration Common
15
1 ~ 300
0.01G
86 Zone 1 maximum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
87 Zone 1 minimum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
88 Zone 1 output number
Common
0
0 ~ 899
Physical output port or global flag (Output is invalid if “0” is set;
multiple specification is invalid)
89 Zone 2 maximum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
90 Zone 2 minimum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
91 Zone 2 output number
Common
0
0 ~ 899
Physical output port or global flag (Output is invalid if “0” is set;
multiple specification is invalid)
92 Zone 3 maximum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum. * Must be inside the range
for at least 3 msec.
93 Zone 3 minimum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
94 Zone 3 output number
Common
0
0 ~ 899
Physical output port or global flag (Output is invalid if “0” is set ;
multiple specification is invalid)
95 Zone 4 maximum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum. > minimum * Must be inside the range
for at least 3 msec.
96 Zone 4 minimum
Common
0
-99999999 ~
99999999 0.001mm
Valid only when maximum > minimum * Must be inside the range
for at least 3 msec.
97 Zone 4 output number
Common
0
0 ~ 899
Physical output port or global flag (Output is invalid if “0” is set;
multiple specification is invalid)
Complete stop mode
transition stop band
Pulse
Motor
Type
4
0 ~ 5
pulse
(For pulse motor)
* Set a value equal to or less than the pulse conversion value in
Each Axis No. 58 “Positioning Band”.
98
System reservation
AC Servo
Motor
Type
0
Deviation buffer number
designation for complete
stop mode transition
judgment
Pulse
Motor
Type
2
0 ~ 4
(For pulse motor)
99
System reservation
AC Servo
Motor
Type
0
100 (For extension)
Common
0
~
101 (For extension)
Common
0
~
102 (For extension)
Common
0
~
103 (For extension)
Common
0
~
104 (For extension)
Common
0
~
105 (For extension)
Common
0
~
106 (For extension)
Common
0
~
107 (For extension)
Common
0
~
108 (For extension)
Common
0
~
109 (For extension)
Common
0
~
110 (For extension)
Common
0
~
111 (For extension)
Common
0
~
112 (For extension)
Common
0
~
113 (For extension)
Common
0
~
114 (For extension)
Common
0
~
115 (For extension)
Common
0
~
116 (For extension)
Common
0
~
117 (For extension)
Common
0
~
118 (For extension)
Common
0
~
119 FSG
Common
0
0 ~ 100
120 FFF
Common
10
0 ~ 100
* Change is prohibited unless instructed by the manufacturer.
121
to
130
(For extension)
Common
0
~
131 (For extension)
Common
0
~
132 Setting bit pattern 3 of
each axis
Common
14H
0H ~
FFFFFFFFH
133 (For extension)
Common
0
~
134 System reservation
Common
0
1 ~ 99999999
135 System reservation
Common
0
1 ~ 99999999
136 System reservation
Common
0
1 ~ 99999999
Содержание TTA Series
Страница 1: ...Tabletop Robot TTA Instruction Manual 12th Edition IAI Corporation ...
Страница 2: ......
Страница 4: ......
Страница 23: ...13 ...
Страница 24: ...14 ...
Страница 25: ...15 ...
Страница 42: ...32 ...
Страница 134: ...124 Chapter 3 Wiring 3 4 Wiring Method ...
Страница 164: ...Chapter 4 Operation 4 8 Payload Adjusted for Setting Values 154 ...
Страница 280: ...Chapter 7 Appendix 7 2 Extension SIO Features 270 ...
Страница 312: ...Chapter 8 Maintenance and Inspection 8 7 Period of Time for Fan Unit Replacement 302 ...
Страница 368: ...Chapter 9 External Dimensions 9 3 Option 358 ...
Страница 370: ...Chapter 10 Life 360 ...
Страница 377: ......