Power Wiring Access –
First, ensure no power source is connected to the inverter. If
power has been connected, verify that the Power LED is OFF and then wait five
minutes after power down to proceed. After removing the terminal cover and front
housing cover, the housing partitions that cover the power and motor wiring exits will
be able to slide upward as shown below.
Notice the four wire exit slots in the housing partition. This helps keep the power and
motor wiring (to the left) separated from the signal-level logic or analog wiring (to the
right).
Remove the housing partition and as shown as set them aside in a secure place while
wiring. Be sure to replace them afterward. Never operate the inverter with the
partition removed or the front housing cover removed.
The power input and motor 3-phase wiring connect to the lower row of the terminals.
The upper row of power terminals connect to optional braking units or DC link choke.
The following section in this chapter will describe system design and guide you through
a step-by-step installation process. After the section on wiring, this chapter will show
how to use the front panel keys to access functions and edit parameters.
Terminal cover
Front cover
Housing partition
NOTE: The h
ousing partition can be removed without removing the front cover in
the following models.
Single-phase 200V: 0.7 to 2.2kW
Three-phase 200V: 1.5 to 15kW
Three-phase 400V: All size
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...