3
−
114
Simple Positioning
Encoder wiring –
The hardware overview about pulse train input is shown bas below.
Pulse input types
Max. Freq.
EA terminal
(5 to 24VDC)
EB terminal
(24VDC)
90
°
ph. difference 2-ph. pulse
2kHz
Phase-A
(PNP open collector or
Voltage output type)
Phase-B
(PNP open collector or
Voltage output type)
Single phase pulse + direction
32kHz
Single phase pulse
(PNP open collector or
Voltage output type)
Direction
(sink/source transistor
or contactor)
Single phase pulse
32kHz
Single phase pulse
(PNP open collector or
Voltage output type)
-
2-phase pulse input
Wire phase-A to EA terminal and phase-B to EB terminal. Since common terminal of EB is
same as other inputs, use all the input terminals as source logic (PNP open collector or
voltage output type). Voltage of EB should be 18 to 24VDC. Assign EB in input terminal 7.
P24
EA
7/EB
PLC
L
PNP open collector type or
voltage output type encoder
Encoder
Vcc
GND
A
B
WJ200
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...