![Hitachi WJ200 Series Software Скачать руководство пользователя страница 191](http://html.mh-extra.com/html/hitachi/wj200-series-software/wj200-series-software_instruction-manual_140866191.webp)
3
−
110
Off-line auto-tuning procedure (with motor rotation)
(Note 2) After auto-tuning is completed, be sure to set 01 in H002/H202, otherwise measured data is
not effective.
(Note 3) Speed "X" of above (5) depends on accel/deceleration time. (T: Larger time of accel or
deceleration time)
0 < T < 50 [s] :
X=40%
50
≤
T < 100 [s] :
X=20%
100
≤
T [s] :
X=10%
(Note 4) If auto-tuning is failed, try to execute again.
(Note 5) If the inverter trips during the auto-tuning, the auto-tuning is interrupted. After removing
the cause of trip, retry auto-tuning from the beginning.
(Note 6) If inverter is stopped during auto-tuning by stop command (by STOP key or deactivate RUN
input), measured constants could remain. Be sure to execute auto-tuning again.
(Note 7) If auto-tuning is attempted in free V/f setting, auto-tuning will fail with error display.
Step 1
: Set motor size and
motor poles
H003
Motor size
Motor poles
Step 2
: Set base freq. and
AVR voltage
Step 3
: Enable auto-tuning
Base freq.
AVR voltage
SET
Step 4
: Start the inverter
according to RUN cmd.
source
RUN
H004
A003
A082
H001
02
Auto-tuning starts.
Result is displayed.
___o
Completed
Failed
___9
Step 5
: Clear display by
STOP key
STOP
Step 6
: Activate motor
constants by H002
SET
H002
02
When RUN cmd. is given, the motor runs according to
following steps.
(1) 1st AC excitation (no rotation)
(2) 2nd AC excitation (no rotation)
(3) 1st DC excitation (no rotation )
(4) V/f operation (80% of base freq.)
(5) SLV operation (X % of base freq.)
(6) 2nd DC excitation (no rotation)
(Note 1): When no-rotation setting (
H001
=
01
), (4) and (5) are skipped.
(Note 1)
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...