3
−
39
(1) Acceleration / deceleration pattern summary
Setting
00
01
02
03
04
Curve Linear
S-curve
U-curve
Inverse
U-curve
EL
S-curve
A097
(Accel.
pattern)
A098
(Decel.
pattern)
Remarks
Standard pattern.
Effective for preventing
the collapse of cargo
carried by lift or
conveyor for example.
Effective for the tension control of winding machine,
to prevent cutting the object to be wound, for
example.
Effective for lift
application because of
the shock less start and
stop.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
t
Freq.
(2)
A131
Curve constant (swelling)
Large
A131
value will result in a big swelling.
A132
is the same concept as above.
(3)
A150
~
a153
Curvature of EL-S-curve
When using EL-S-curve pattern, you can set the curvatures individually for acceleration
and deceleration. If all the curvatures are set to 50%, the EL-S-curve pattern will be
equivalent to the S-curve pattern.
Freq.
S-curve
t
0
A097
=
01
A131
=
10
A131
=
02
Freq.
U-curve
t
0
A097
=
02
A131
=
10
A131
=
02
Freq.
Inverse U-curve
t
0
A097
=
03
A131
=
10
A131
=
02
Curvature for
acceleration 2
0
A151
A150
Curvature for
acceleration 1
A152
Curvature for
deceleration 1
t
A153
Curvature for
deceleration 2
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...