4
−
83
Window Comparator for Analog Inputs
The window comparator function outputs signals when the value of analog inputs [O]
and [OI] are within the maximum and minimum limits specified for the window
comparator. You can monitor analog inputs with reference to arbitrary levels (to find
input terminal disconnection and other errors).
Refer to chapter 3 for detailed information.
Option
Code
Terminal
Symbol
Function Name
State
Description
54
WCO
Window comparator for
analog voltage input
ON
[O] input is inside of the window comparator
OFF [O] input is outside of the window comparator
55
WCOI
Window comparator for
analog current input
ON
[OI] input is inside of the window comparator
OFF [OI] input is outside of the window comparator
Valid for inputs:
11, 12, AL0 – AL2
Example for terminal [11] (default output
configuration shown – see
page 3-90
):
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
page 4-52 and 3-90
):
See I/O specs on
page 4-6
Required settings
b060
~
b065
,
b070
,
b071
Notes:
- Output values of ODc and OIDc are the same as
those of WCO and WCOI, respectively.
RY
Inverter output
terminal circuit
CM2
11
WCO
AL1
Power
supply
Load
AL0
AL2
Inverter logic
circuit board
WCO
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...