x
Warnings and Cautions for Troubleshooting and Maintenance
WARNING: Wait at least five (5) minutes after turning OFF the input power
supply before performing maintenance or an inspection. Otherwise, there is the
danger of electric shock.
…
6-2
WARNING: Make sure that only qualified personnel will perform maintenance,
inspection, and part replacement. Before starting to work, remove any metallic
objects from your person (wristwatch, bracelet, etc.). Be sure to use tools with
insulated handles. Otherwise, there is a danger of electric shock and/or injury to
personnel.
…
6-2
WARNING: Never remove connectors by pulling on its wire leads (wires for cooling
fan and logic P.C.board). Otherwise, there is a danger of fire due to wire breakage
and/or injury to personnel.
…
6-2
CAUTION: Do not connect the megger to any control terminals such as intelligent
I/O, analog terminals, etc. Doing so could cause damage to the inverter.
…
6-10
CAUTION: Never test the withstand voltage (HIPOT) on the inverter. The inverter
has a surge protector between the main circuit terminals above and the chassis
ground.
…
6-10
CAUTION: Do not connect the megger to any control circuit terminals such as
intelligent I/O, analog terminals, etc. Doing so could cause damage to the inverter.
…
6-10
CAUTION: Never test the withstand voltage (HIPOT) on the inverter. The inverter
has a surge protector between the main circuit terminals above and the chassis
ground.
…
6-10
HIGH VOLTAGE: Be careful not to touch wiring or connector terminals when
working with the inverters and taking measurements. Be sure to place the
measurement circuitry components above in an insulated housing before using
them.
…
6-14
General Warnings and Cautions
iv
WARNING: Never modify the unit. Otherwise, there is a danger of electric shock and/or injury.
CAUTION: Withstand voltage test and insulation resistance tests (HIPOT) are executed before
the units are shipped, so there is no need to conduct these tests before operation.
CAUTION: Do not attach or remove wiring or connectors when power is applied. Also, do not
check signals during operation.
CAUTION: Be sure to connect the grounding terminal to earth ground.
CAUTION: When inspecting the unit, be sure to wait five minutes after turning OFF the power
supply before opening the cover.
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...