![Hitachi WJ200 Series Software Скачать руководство пользователя страница 363](http://html.mh-extra.com/html/hitachi/wj200-series-software/wj200-series-software_instruction-manual_140866363.webp)
B
−
34
Register
No.
Function name
Function code
R/W
Monitoring and setting items
Data
resolution
126Fh to
1273h
(Reserved) -
-
-
1274h
Acceleration time (2)
A092 (high)
R/W
1 to 360000
0.01 [sec.]
1275h A092
(low)
R/W
1276h
Deceleration time (2)
A093 (high)
R/W
1 to 360000
0.01 [sec.]
1277h A093
(low)
R/W
1278h
Select method to switch to
Acc2/Dec2 profile
A094 R/W
0 (switching by 2CH terminal), 1 (switching by
setting)
2 (Forward and reverse)
-
1279h
Acc1 to Acc2 frequency
transition point
A095 (high)
R/W
0 to 40000(100000)
0.01 [Hz]
127Ah A095
(low)
R/W
127Bh
Dec1 to Dec2 frequency
transition point
A096 (high)
R/W
0 to 40000(100000)
0.01 [Hz]
127Ch A096
(low)
R/W
127Dh
Acceleration curve
selection
A097 R/W
0 (linear), 1 (S curve), 2 (U curve), 3
(inverted-U curve), 4 (EL-S curve)
-
127Eh
Deceleration curve setting
A098
R/W
0 (linear), 1 (S curve), 2 (U curve), 3
(inverted-U curve), 4 (EL-S curve)
-
127Fh (Reserved)
-
-
-
-
1280h (Reserved)
-
-
-
-
1281h
[OI] input active range start
frequency
A101 (high)
R/W
0 to 40000(100000)
0.01 [Hz]
1282h A101
(low)
R/W
1283h
[OI] input active range end
frequency
A102 (high)
R/W
0 to 40000(100000)
0.01 [Hz]
1284h A102
(low)
R/W
1285h
[OI] input active range start
current
A103
R/W 0 to "[OI]-[L] input active range end current"
1 [%]
1286h
[OI] input active range end
current
A104 R/W
"[OI]-[L] input active range start current" to
100
1 [%]
1287h
[OI] input start frequency
select
A105
R/W 0 (external start frequency), 1 (0 Hz)
-
1288h to
12A4h
(Reserved) -
-
-
-
12A5h
Acceleration curve constant
A131
R/W
1 (smallest swelling) to 10 (largest swelling)
-
12A6h
Deceleration curve
constant
A132
R/W 1 (smallest swelling) to 10 (largest swelling)
-
12A7h to
12AEh
(Reserved) -
-
-
-
12AFh
Operation-target frequency
selection 1
A141 R/W
0 (digital operator), 1 (keypad potentiometer),
2 (input via O), 3 (input via OI), 4 (external
communication), 5 (option ), 7 (pulse train
frequency input)
-
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...